Register to unlock your exclusive B2B prices and start shopping. Sign up now!
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 1
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 2
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 3
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 4
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 5
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 6
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 7
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG image 8
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 1
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 2
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 3
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 4
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 5
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 6
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 7
ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG thumbnail 8

ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG

Order only
Price (excl. VAT):
7,61 €
This price is valid until 24.12.26
EAN: 4044777341535
MPN: 2170905
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name ETHERLINE FIRE Cat.5e PH120 4x2x23/1 AWG
Brand LAPP
Categories Ethernet cable (network)
Country of origin* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8544 4995 00
Nominal cross section conductor 2 mm²
Colour outer sheath Red
Conductor material Copper
Permitted cable outer temperature during assembling/handling 0 °C
Permitted cable outer temperature after assembling without vibration -20-70 °C
Number of cores 4
Halogen free according to IEC 60754-2 No
Low smoke according to IEC 61034-2 Yes
Outer diameter approx. 8.6 mm
Conductor surface Bare
Min. permitted bending radius, stationary application/permanent installation 133.5 mm
Flame retardant according to IEC 60332-1-2 Yes
Flame retardant according to IEC 60332-3-21 (Cat A F/R) No
Flame retardant according to IEC 60332-3-22 (Cat A) No
Flame retardant according to IEC 60332-3-23 (Cat B) No
Flame retardant according to IEC 60332-3-24 (Cat C) No
Flame retardant according to IEC 60332-3-25 (Cat D) No
Halogen free according to IEC 60754-1 Yes
Halogen free according to IEC 60754-3 No

Packing details

Packing level 1 4044777341535, 4044777341566, 4044777341542, 4044777341559

Downloads

Description

Voordelen; Gegarandeerde gegevensoverdracht in geval van brand gedurende 120 min. (volgens EN50200) Hoogwaardige tweevoudige afscherming garandeert een hoge overdrachtveiligheid in elektromagnetisch belaste gebieden Toepassing; In industriële omgevingen met hoge temperaturen Licht brandbare of brandgevaarlijke plaatsen voor vaste installatie Voor binnengebruik