Register to unlock your exclusive B2B prices and start shopping. Sign up now!
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 1
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 2
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 3
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 4
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 5
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 6
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 7
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval image 8
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 1
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 2
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 3
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 4
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 5
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 6
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 7
KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval thumbnail 8

KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval

Order only
Price (excl. VAT):
3,91 €
This price is valid until 24.12.25
EAN: 4044773073003
MPN: 0163006
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name KP4L-S PtRh/Pt RCB,SCB 2X1,5 IEC oval
Brand LAPP
Categories Fireproof cables
Country of origin* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8544 4993 00
Nominal cross section conductor 1.5 mm²
Material core insulation Other
Armouring Yes
Colour outer sheath Orange
Screen over stranding element None
Screen over stranding None
Material outer sheath Other
Material conductor 2 CuNi
Number of thermo-pairs 1
Min. permitted bending radius, stationary application/permanent installation 70.8 mm

Packing details

Packing level 1 4044773073003, 4044774677903, 4044774677910, 4044774677897

Downloads

Description

Voordelen; Ruimtebesparend en flexibel Voor meer informatie, zie appendix T8 en data sheets Toepassing; In de omgeving van de temperatuurmeting resp. productprocesbesturing in combinatie met een thermisch ommantelingselement. Het isolatiemateriaal moet overeenkomstig de maximale omgevingstemperatuur op de aansluitkop van het thermische element worden gekozen. Geleidermaterialen (legeringen):Fe/CuNi (LX, JX)Geleiderlegeringen zijn identiek aan de legeringen van het thermokoppelelement NiCr/Ni (K, KX, KCA) K- en KX-uitvoering - geleiderlegeringen zijn identiek aan de thermokoppellegeringen KCA-uitvoering: compenserende legeringen (voor KCA: Fe/CuNi) niet identiek aan thermokoppellegeringen PtRh/Pt (RCB, SCB)Compenserende legeringen (voor RCB, SCB: Cu/CuNi) zijn niet identiek aan thermokoppellegeringen Maakt temperatuurmeting mogelijk op plaatsen waar contactloze temperatuurmeting niet mogelijk is