| Item condition |
New |
| Manufacture name |
KNX CABLE BUS 500 M. |
| Brand |
Legrand
|
| Categories |
Power cables
|
| Country of origin* |
DE |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Harmonized System Code |
8544 4920 00
|
| Nominal cross section conductor |
0.8 mm² |
| Material core insulation |
Other |
| Core identification |
Colour |
| Flame retardant |
No |
| Armouring |
No |
| Lead sheath |
No |
| Drain wire |
Yes |
| Colour outer sheath |
Green |
| Shape of conductor |
Round |
| Conductor material |
Copper |
| Material outer sheath |
Other |
| Conductor category |
Class 2 = stranded |
| Laminated sheath |
No |
| Fibre optic elements |
No |
| Permitted cable outer temperature during assembling/handling |
-25-70 °C |
| Permitted cable outer temperature after assembling without vibration |
-25-70 °C |
| Number of pilot/reduced conductors |
0 |
| Inner semi-conducting layer |
No |
| Outer semi-conducting layer |
No |
| Longitudinal water blocking screen |
No |
| Nominal voltage U0 |
2.5 kV |
| Screen |
Yes |
| Number of cores |
2 |
| Longitudinal water blocking conductors |
No |
| Nominal cross section concentric conductor |
0.5 mm² |
| Halogen free according to IEC 60754-2 |
No |
| Insulation integrity according to IEC 60331 |
No |
| Concentric conductor |
Copper |
| Low smoke according to IEC 61034-2 |
No |
| Outer diameter approx. |
5.5 mm |
| With protective conductor |
No |
| Low smoke (according to EN 61034-2) |
Yes |
| Conductive coating |
No |
| Halogen free according to EN 60754-1/2 |
No |
| Oil resistant (according to IEC 60811-404) |
No |
| Core identification according to HD 308 S2 |
No |
| Suitable as installation cable |
No |
| Certified for shipboard application |
No |
| Suitable as medium-voltage cable |
No |
| Suitable as high-voltage cable |
No |
| Certified as airport lighting cable |
No |
| Circuit integrity according to BS 6387 CWZ |
No |
| Circuit integrity according to EN 50200 annex E |
No |
| Circuit integrity according to BS 8434-2 |
No |
| Circuit integrity according to IEC 60331-21 |
No |
| Flame retardant according to EN 60332-1-2 |
No |
| Flame retardant according to EN 60332-3-21 (Cat A F/R) |
No |
| Flame retardant according to EN 60332-3-22 (Cat A) |
No |
| Flame retardant according to EN 60332-3-23 (Cat B) |
No |
| Flame retardant according to EN 60332-3-24 (Cat C) |
No |
| Flame retardant according to EN 60332-3-25 (Cat D) |
No |
| Halogen free according to EN 60754-1 |
No |
| Halogen free according to EN 60754-2 |
No |
| Halogen free according to EN 60754-3 |
No |