| Voltage type | AC | 
                                                                    
                                        | Built-in depth | 45 mm | 
                                                                    
                                        | Rated insulation voltage Ui | 500 V | 
                                                                    
                                        | Surge current capacity | 0.25 kA | 
                                                                    
                                        | Current limiting class | 3 | 
                                                                    
                                        | Over voltage category | 3 | 
                                                                    
                                        | Pollution degree | 2 | 
                                                                    
                                        | Width in number of modular spacings | 2 | 
                                                                    
                                        | Frequency | 50 Hz | 
                                                                    
                                        | Concurrently switching neutral conductor | Yes | 
                                                                    
                                        | Rated short-circuit breaking capacity according to IEC 60947-2 | 15 kA | 
                                                                    
                                        | Connectable conductor cross section solid-core | 1-35 mm² | 
                                                                    
                                        | Connectable conductor cross section multi-wired | 1-25 mm² | 
                                                                    
                                        | With interlocking device | No | 
                                                                    
                                        | Anti-nuisance tripping version | No | 
                                                                    
                                        | Rated impulse withstand voltage Uimp | 4 kV | 
                                                                    
                                        | Rated short-circuit breaking capacity Icn according to EN 61009-1 | 0 kA | 
                                                                    
                                        | Disconnection characteristic | Undelayed | 
                                                                    
                                        | Rated short-circuit breaking capacity according to EN 61009 | 0 kA |