Technical Information
| Item condition |
New |
| Manufacture name |
HALOLINE® PRO 80 W 230 V R7S |
| Brand |
OSRAM
|
| Categories |
R7s Light Bulbs
R7s Halogen Lamps
|
| Country of origin |
CN |
| Harmonized System Code |
8539 2192 00
|
| Energy Class |
G
|
| EPREL - European Product Registry for Energy Labelling |
714451
|
| Model |
Clear |
| Socket |
R7s |
| Luminous flux |
1400 lm |
| Total length |
74.9 mm |
| Diameter |
12 mm |
| Lamp shape |
Tube, double-ended |
| Lamp voltage |
230 V |
| Colour temperature |
2900 K |
| Lamp power |
80 W |
Packing details
| Packing level 1 |
4008321928078 |
| Packing level 2 |
4008321327758 |
| Packing level 3 |
4008321928078 |
Other Technical data
| UV-protection |
No |
| Infrared coating/-technique |
No |
| Twisted glass |
No |
| Average nominal lifespan |
2000 h |
| Weighted energy consumption in 1000 hours |
80 kWh |
| Lamp designation |
T4 |
| Energy efficiency class according to EU regulation 2019/2015 |
G |
Downloads
Description
This component is a compact fluorescent tube designed for energy-efficient lighting in industrial, commercial, or residential luminaires. It provides stable, high-lumen output with reduced power consumption compared to traditional incandescent lamps and offers compatibility with specific electronic ballasts.
### Electrical Characteristics
- Operates at 18 watts under standard conditions.
- Requires a compatible G24q-2 socket for secure installation.
- Designed to function on a nominal voltage supply via appropriate electronic control gear.
### Physical Specifications
- Compact form factor with double-turn tubular design (twin-tube).
- Length: Approximately 145 mm; Diameter: Roughly 12 mm per tube section.
- Color rendering index (CRI): ≥80 — suitable for general-purpose environments requiring moderate color accuracy.
### Technical Notes or Limitations
- Not dimmable; do not use with dimming systems.
- Only works in fixtures equipped with ballasts matching the lamp specs—check datasheets before installing.
- Operating temperature range: Limited performance below -10°C or above +35°C may occur.
- Contains a small quantity of mercury—follow disposal regulations strictly after end-of-life cycle.