PT 2,5-PE - Ground terminal
In stock: Yes
Vendor stock: Yes
Minimal order quantity: 50
Price (excl. VAT):
1,06 €
per pcs
This price is valid until 31.12.25 or while stock lasts
Subtotal: 53,00 €
MOQ: 50
Estimate delivery time at our warehouse (approx.):
2-4 weeks
Technical Information
Item condition |
New |
Manufacture name |
PT 2,5-PE - Ground terminal |
Brand |
Phoenix Contact
|
Categories |
DIN Rail Terminal Blocks
|
Country of origin |
DE |
Harmonized System Code |
8536 9010 00
|
Mounting method |
DIN rail (top hat rail) 35 mm |
Type of electrical connection 1 |
Other |
Type of electrical connection 2 |
Other |
PEN function possible |
No |
Number of levels |
1 |
Number of clamp positions per level |
2 |
Connectable conductor cross section solid-core |
0.14-4 mm² |
Connectable conductor cross section fine-strand with cable end sleeve |
0.14-2.5 mm² |
Connectable conductor cross section fine-strand without cable end sleeve |
0.14-4 mm² |
Connectable conductor cross section multi-wired |
0.14-4 mm² |
Packing details
Packing level 1 |
4046356329804, 4046356329804 |
Other Technical data
Colour |
Other |
Width |
5.15 mm |
Height |
49.1 mm |
Depth |
35.25 mm |
Operating temperature |
105 °C |
Inflammability class of insulation material according to with UL94 |
V0 |
Closing plate required |
Yes |
Material insulation body |
Other |
Description
This part serves as a capacitive sensor for detecting liquid levels in tanks and containers. It operates by monitoring the changes in capacitance caused by variations in the dielectric properties of the medium surrounding its probe. Designed for non-invasive measurements or direct immersion, depending on installation requirements.
### Electrical Specifications
Operating voltage: 10–30 VDC.
Current consumption typically ≤15 mA under standard conditions.
Output type: PNP, normally open configuration; capable of reliable switching within designated tolerances when threshold is met.
### Mechanical Details
Enclosure material: Polyamide housing with high chemical resistance, suitable for industrial use cases.
Connection: 3-wire cable setup with M12 connector (standard). Support sealing level IP67 against dust and water ingress.
- Temperature range during operation should stay between -25°C to +70°C; exposure beyond this can impair functionality.
- Not recommended for highly conductive liquids without calibration adjustment.
- Maximum sensing distance depends on fluid density—verify prior to deployment.
- Avoid proximity to high-frequency EMI sources during installation; may cause interruptions.