Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 1
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 2
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 3
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 4
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 5
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker image 6
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 1
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 2
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 3
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 4
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 5
Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker thumbnail 6

Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker

Order only Minimal order quantity: 3 Not Available
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2", 51 x 192 mm, back-up, DIN, with striker
Brand EATON
Country of origin* HU
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8535 1000 00
Application Primary side transformer protection
Voltage type AC
Rated current 31.5 A
Rated voltage 3.6 kV
Rated frequency 50 Hz
Utilization category Other
Breaking capacity 40 kA

Packing details

Packing level 1 5027590473743
Packing level 2 5027590095013

Other Technical data

Diameter 51 mm
Release characteristic Other
Length 192 mm
Installation technique Air
With striker Yes
Standard DIN
Performance category according to IEC 60282-1 Back-up

Description

Fuse, Fuse-link, medium voltage, 31.5 A, AC 3.6 kV, 2z, 51 x 192 mm, Back-up, DIN, with striker, transformer protection, indoor use, DIN 43625, VDE 0670 Part 4, IEC 60282-1, Breaking Capacity 40 kA