Technical Information
| Item condition |
New |
| Manufacture name |
FO DCA INOUT TB OM3 50/125 6FO 2100M |
| Brand |
Schneider Electric
|
| Categories |
Fibre optic cables
|
| Country of origin* |
SK |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| ETIM |
EC000034
|
| Fibre type |
Multi mode 50/125 |
| Number of fibres |
6 |
| With strain relief |
No |
| Material outer sheath |
Other |
| Type of tube |
Tight |
| Number of fibres per tube |
6 |
| Outer diameter approx. |
6.5 mm |
Packing details
| Packing level 1 |
3606481319555 |
Other Technical data
| UV resistant |
Yes |
| Weight |
0 kg/km |
| Flame retardant |
According to IEC/EN 60332-1-2 |
| Armouring |
No |
| Resistant to chemicals |
No |
| Colour outer sheath |
Green |
| Category |
OM3 |
| Cable metal free |
Yes |
| Blow in |
No |
| With rodent protection |
Yes |
| Low smoke (according to EN 61034-2) |
Yes |
| Halogen free according to EN 60754-1/2 |
Yes |
| Oil resistant according to IEC 60811-404 |
No |
| Longitudinal water blocking cable |
Yes |
| Radial water blocking cable |
No |
| Reaction-to-fire according to EN 13501-6: Class |
Dca |
| Reaction-to-fire according to EN 13501-6: Smoke production |
s2 |
| Reaction-to-fire according to EN 13501-6: Flaming droplets/particles |
d2 |
| Reaction-to-fire according to EN 13501-6: Acidity |
a2 |
| Min. permitted bending radius, stationary application/permanent installation |
65 mm |
| Specification material outer sheath |
Other |
| Max. tensile strength during installation |
0 kN |
Description
This 6 fibres tight buffered Fibre optic cable is a compact and universal cable suitable for indoor and specific outdoor installations. It features with low Smoke Zero Halogen (LSZH) green coloured external sheath, UV resistant, dielectric, high tensile strength, rodent retardant and longitudinally watertight. It is tight buffered gel-free cable construction with 900 µm coating. Its flame retardant according to EN 50575standard and new European Commission - Construction Progduct Regulution (CPR) Euroclass DCA. Its multimode OM3 50/125 optical performance is compliant with ITU G.651, IEC 60793-2-10 Type A1a.2 and ISO/IEC 11801 - 2011 Ed2.2 OM3. The cable mechanical characteristics tested according to IEC 60794-1. It is used for high data rate fibre optic backbones for building and campus, horizontal cable for FTTD Fibre to the desk. Suitable for direct termination with connectors of cold-cured and/or heat-cured types. The cable length is at 2,100 meters per reel.