Item condition | New |
Manufacture name | F/FTP 4P 500M CAT6A 500MHZ LSZH DCA |
Brand | Schneider Electric |
Categories |
Ethernet cable (network)
|
Country of origin | FR |
Harmonized System Code | 8544 4993 00 |
UV resistant | No |
Nominal cross section conductor | 0.25 mm² |
Core identification | Colour |
Weight | 0 kg/km |
Flame retardant | According to IEC/EN 60332-1-2 |
Stranding element | Pairs |
Colour outer sheath | Blue |
Category | 6A (IEC) |
Diameter conductor | 0.565 mm |
Screen over stranding element | Foil |
Screen over stranding | Foil |
Conductor category | Class 1 = solid |
Permitted cable outer temperature during assembling/handling | 0-50 °C |
Permitted cable outer temperature after assembling without vibration | -20-60 °C |
Number of stranding elements | 4 |
Number of cores | 8 |
Suitable for underground installation | No |
Halogen free according to IEC 60754-2 | Yes |
Insulation integrity according to IEC 60331 | No |
Low smoke according to IEC 61034-2 | Yes |
Outer diameter approx. | 7 mm |
Low smoke (according to EN 61034-2) | Yes |
NVP value | 80 % |
Halogen free according to EN 60754-1/2 | Yes |
Oil resistant according to IEC 60811-404 | No |
Oil resistant (according to IEC 60811-404) | No |
Conductor surface | Bare |
Longitudinal water blocking cable | No |
Radial water blocking cable | No |
Reaction-to-fire according to EN 13501-6: Class | Dca |
Reaction-to-fire according to EN 13501-6: Smoke production | s2 |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | d1 |
Reaction-to-fire according to EN 13501-6: Acidity | a1 |
Min. permitted bending radius, moving application with forced guidance | 0 mm |
Min. permitted bending radius, moving application/free movement | 0 mm |
Min. permitted bending radius, stationary application/permanent installation | 28 mm |
Specification core insulation | Polyethylene (PE) |
Specification material outer sheath | Polyethylene (PE) |
Packing level 1 | 3606481320292 |
"Delivers high-performance connections in a network setup. Reliable data transmission for demanding environments, supports speeds up to 10Gbps over extended distances. Used for structured cabling, compatible with CAT6A systems.
500MHz bandwidth support, reduces signal interference via F/FTP shielding design (foil around each pair + overall foil). Low-smoke zero-halogen (LSZH) outer sheath suited for installations where fire safety is critical. Complies with Dca Euroclass flame rating regulations, useful for public buildings or restricted areas requiring strict standards. Length supplied: 500 meters.
Raw technical notes:
Category 6A Ethernet cable. Shielded: F/FTP (foil per pair + overall foil). Frequency: 500 MHz range. Jacket material LSZH, reduces toxic emissions during combustion. Rated Dca - s2, d2, a1 fire class under EN50575 CPR regulation.