Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
VIGILOHM IM400 110/440VACDC 50/60/400HZ image 1

VIGILOHM IM400 110/440VACDC 50/60/400HZ

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
1 689,41 €
Hind kehtib kuni 31.12.25
EAN: 3606480573347
MPN: IMD-IM400
Pakend: 1
Hinnanguline tarneaeg meie laos (umbes): Päringu alusel

Technical Information

Toote seisukord Uus
Tootja nimi VIGILOHM IM400 110/440VACDC 50/60/400HZ
Bränd Schneider Electric
Kategooriad Monitoring Relays
Päritoluriik IN
Funktsioon Segasüsteemile
Isolatsioonitakistuse näit Yes
Võimalik on vigade registreerimine Yes
Näivtakistuse 1 väärtus 1-1000 kOhm
Näivtakistuse 2 väärtus 0.1-500 kOhm
Normaalselt suletud kontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 3606480573347

Muud tehnilised andmed

Laius 159 mm
Kõrgus 123 mm
Sügavus 90 mm
Nimisagedus 45-440 Hz
Eemaldatavate klambritega Yes
Liini võimsus 500 µF
Elektriühenduse liik Kruviühendus
Tunnuspinge 1000-1700 V
Juhtahelate tunnus-toitepinge, AC 50 Hz 110-440 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 100-440 V
Juhtahelate tunnus-toitepinge, DC 100-440 V
Aktiveerimispinge liik AC
Normaalselt avatud kontaktide arv 0
Ümberlülituskontaktide arv 2

Kirjeldus

This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards. According to standards, it is recommanded to equip your systems with Insulation Monitoring Devices (IMD). This device is dedicated to monitoring large and disturbed AC, DC and ACDC systems. It mesures the system insulation resistance by injecting a low frequency AC current between the network and ground. Configuration will be set depending on the installation. Settings are available on the front of the device, through the HMI screen, or from the communication port. Settings are related to network type, alarm and pre-alarm thresholds, alarm delay from 0 to 7200 secondes, and others are available. It monitors networks up to 830VAC when connected to neutral, 480V when connected to line, and 480VDC, with up to 500microfarad. The black and white screen can displays insulation resistance from 10 ohms to 10 megohms, capacitance and temporary faults. Auto-test starts automatically every 5 hours, and on demand. In case the system insulation resistance drops below the set threshold, meaning a ground fault occurred, an alarm is triggered thru the IMD output relay. Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal. The device can be supplied by a 110VAC to 440VAC source or a 110VDC to 440VDC, all with a tolérence of plus or minus 15%. This product is installed flush mounted, an enclosure door for example. Front face ingress protection is IP5, rear IP20 and overvolage 300V category III. The monitoring device is equipped with a RS485 communication port, Modbus protocol.