VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC image 1
VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC image 2
VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC image 3
VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC thumbnail 1
VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC thumbnail 2
VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC thumbnail 3

FCC/S1.3.2.1 Fan Coil Controller, 3 x 0-10 V, Manual Operation, MDRC

Ainult telli
EAN: 4016779011488
MPN: 2CDG110216R0011
Pakend: 1
Hind (ilma KM-ta)
778,31 €
tk kohta
Minimaalne tellimiskogus: 1
Hinnanguline tarneaeg meie laos: Päringu alusel
Hind kehtib kuni 31.12.30 või kuni kaupa jätkub

Tehniline teave

Toote seisukord Uus
Tootja nimi VC/S4.1.1 Valve Drive Controller, 4-fold, MDRC
Bränd ABB
Kategooriad Siini-süsteemi seadmed (KNX & Modbus)
Harmoneeritud süsteemi kood 8537 1091 00
ETIM EC001586
Paigaldusviis DRA (DIN liistule)
Väljundite arv 4
Suurim väljundvool 0.25 A
Siinisüsteem KNX Jah
Raadiosageduslik siinisüsteem Ei
Muud siinisüsteemid Puudub
Parandusmuutuja consistent Jah
Lülituse korrektsioon Correcting variable switching Jah
Kaitseklapifunktsioon Valve protection function Jah
Käsitsi aktiveerimine Ei

Pakendamise üksikasjad

Pakkimistase 1 4016779011488

Muud tehnilised andmed

Suurim lülitusvool (aktiivkoormus) 0.25 A
Siinisüsteem Powernet Ei
Siiniühendusega Jah
Digitaalsisendite arv 0
Laius mooduli arvudes 8
Siinisüsteem LON Ei
Lülituspinge 230 V
Kaitseaste (IP) IP20
Siinisüsteem KNX radio Ei
Raadiosageduslik, kahesuunaline Ei
Eemaldatav siini moodul Ei
Sisseehitatud paigalduskarbi vähim sügavus 64.5 mm

Allalaadimised

Kirjeldus

For the control of heating and cooling applications in the room, such as radiator, floor heating or cooling ceiling. The device has 4 channels each for the independent control of a heating or cooling application. Each channel has an electronic valve output for the control of a thermoelectric valve drive, as well as 3 inputs to detect and monitor the room status (use for window contact, dew point sensor, level sensor or temperature sensor). Also it is possible to connect one analog room control unit (SAR/A or SAF/A) to the inputs of each channel. Each channel has its own integrated room temperature controller for the control of the room temperature, which can be used directly to control the outputs of the device. The device supports the ABB i-bus Tool for advanced diagnosis and improved commissioning.