Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 1
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 2
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 3
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 4
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 5
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 6
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 7
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 8
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 9
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 10
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 11
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 12
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 13
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 14
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 15
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 16
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 17
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O image 18
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 1
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 2
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 3
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 4
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 5
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 6
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 7
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 8
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 9
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 10
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 11
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 12
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 13
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 14
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 15
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 16
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 17
NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O thumbnail 18

Shunt release, 380-440VAC/DC, +1early N/O

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
60,25 €
Hind kehtib kuni 24.12.25
EAN: 4015082598204
MPN: 259820
Pakend: 1
Hinnanguline tarneaeg meie laos (umbes): 8-10 weeks

Technical Information

Toote seisukord Uus
Tootja nimi NZM2/3-XAHIV380-440AC/DC Shunt release, 380-440VAC/DC, +1early N/O
Bränd EATON
Kategooriad Trip & Release Units
Päritoluriik RO
Harmoneeritud süsteemi kood 8538 9099 00
Elektriühenduse liik Kruviühendus
Juhtahelate tunnus-toitepinge, AC 50 Hz 380-440 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 380-440 V
Juhtahelate tunnus-toitepinge, DC 380-440 V
Viivituseta lühisvabasti sättepiirkonna algväärtus 0 A
Viivituseta lühisvabasti sättepiirkonna lõppväärtus 0 A
Aktiveerimispinge liik AC/DC

Pakendamise üksikasjad

Pakkimistase 1 4015082598204

Muud tehnilised andmed

Sobib lahklülitile Yes
Sobib liigkoormusreleele No
Sobib mootorikaitselülitile No
Sobib toiteahela kaitselülitiks No
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0

Kirjeldus

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: cannot be used in conjunction with NZM...-XR... remote operator. If the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented. early make of auxiliary contact on switching on and off (manual operation): approx. 20ms . Undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XU.. shunt release. Can be used for: NZM2(-4), N(N/O)2(-4), NZM3(-4), N(N/O)3(-4)