Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink terminals
Laos: Ei
Hankija laovaru: Ei
Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
256,65 €
Hind kehtib kuni 24.12.25
Pakend: 1
Karp: 5
Kaubaalus: 216
Hinnanguline tarneaeg meie laos (umbes):
4-6 weeks
Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink terminals |
Bränd |
Schneider Electric
|
Kategooriad |
Mootori kaitselülitid
|
Päritoluriik |
PL |
Harmoneeritud süsteemi kood |
8536 2010 00
|
Nominaalne püsivool Iu |
3.5 A |
Pooluste arv |
3 |
Tunnus-talitluspinge |
0-690 V |
Liigkoormuskaitse sättepiirkond |
1.4-3.5 A |
Kaitseaste (IP) |
IP40 |
Nimi lahutusvõime lühisel Icu 400 V AC korral |
100 kA |
Viivituseta lühisvabasti seadistuspiirkond |
60 A |
Pakendamise üksikasjad
Pakkimistase 1 |
3606481386458 |
Pakkimistase 2 |
3606481386456 |
Pakkimistase 3 |
3606481386458 |
Muud tehnilised andmed
Laius |
81 mm |
Kõrgus |
155 mm |
Sügavus |
116 mm |
Tunnustalitlusvõimsus, AC-3, 400 V |
1.5 kW |
Sisseehitatud abilülitiga |
No |
Sisseehitatud alapingevabastiga |
No |
Termokaitsega |
Yes |
Peaahela ühendusviis |
Kruviühendus |
Juhtelemendi liik |
Juhthoob |
Väljalülituspõhimõte |
Elektrooniline |
Nominaalne käitusvõimsus AC-3, 230 V korral |
0.75 kW |
Faasirikketundlik |
Yes |
Seadme ehitus |
Komplektne seade korpuses |
Allalaadimised
Kirjeldus
TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).