Technical Information

Toote seisukord Uus
Tootja nimi Analogue settable multifunction time relay, 1 NO contact 10A
Bränd ELTAKO
Kategooriad Marking Plates and Enclosures
Päritoluriik* CN
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Funktsioon Mitmeotstarbeline
Aktiveerimismoodus Analoog, multifunktsionaalne
Laius mooduli arvudes 1
Ümberlülitite arv 0
Toitepinge liik AC
Toitepinge 230 V
1. intervalliüksus Minutit/tundi
1. intervall 0.1-40
Nimilülitusvool pingel 250 V AC 10 A
Hõõglampide lülitusvõime 1000 W
Luminofoorlampide lülitusvõime, induktiivkoormus 500 VA
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1

Pakendamise üksikasjad

Pakkimistase 1 4010312603147, 4010312603147
Pakkimistase 2 4010312603147
Pakkimistase 3 4010312603147

Muud tehnilised andmed

Kõrgus 58 mm
Juhtpinge 1 230 V
Juhtpinge 1 liik AC
Juhtpinge 1 sagedus 50 Hz
Luminofoorlampide lülitusvõime DUO 500 VA
Luminofoorlamide lülitusvõime, rööpühenduses 250 VA

Allalaadimised

Kirjeldus

1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 1000W*. Standby loss 0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Control voltage 230V. Supply voltage same as control voltage. Time setting between 0.1 second and 40 hours. Functions F: RV = off delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled operate delay (e.g. automatic door opener). EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = permanent ON. OFF = permanent OFF. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact is open, and is continuously ON as long as the relay contact is closed. The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.