Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ image 1
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ image 2
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ image 3
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ image 4
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ thumbnail 1
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ thumbnail 2
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ thumbnail 3
Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ thumbnail 4

Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ

Ainult telli
Hind (ilma KM-ta):
365,90 €
Hind kehtib kuni 24.12.26
EAN: 4015081788101
MPN: 184774
Pakend: 1
Hinnanguline tarneaeg meie laos (umbes): 4-6 weeks

Technical Information

Toote seisukord Uus
Tootja nimi Insulation monitoring relays, 0 - 400 V AC, 0 - 600 V DC, 1 - 100 kΩ
Bränd EATON
Kategooriad Monitoring Relays
Päritoluriik* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmoneeritud süsteemi kood 8536 4900 00
Funktsioon Segasüsteemile
Isolatsioonitakistuse näit No
Võimalik on vigade registreerimine Yes
Näivtakistuse 1 väärtus 1-100 kOhm
Näivtakistuse 2 väärtus 1-200 kOhm
Normaalselt suletud kontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4015081788101

Muud tehnilised andmed

Laius 45 mm
Kõrgus 85.6 mm
Sügavus 107 mm
Nimisagedus 15-60 Hz
Eemaldatavate klambritega No
Liini võimsus 20 µF
Elektriühenduse liik Kruviühendus
Tunnuspinge 0-400 V
Juhtahelate tunnus-toitepinge, AC 50 Hz 24-240 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 24-240 V
Juhtahelate tunnus-toitepinge, DC 24-240 V
Aktiveerimispinge liik AC/DC
Normaalselt avatud kontaktide arv 0
Ümberlülituskontaktide arv 2

Kirjeldus

Insulation monitoring relays, Product range: EMR Measuring and monitoring relays, Status indication via LEDs, Open-circuit principle, Test or reset with button on device or with control input, Configurable fault memory/memory function, Configurable non-volatile fault memory, Wire break detection, Monitoring of: Insulation resistance in non-earthed AC supply systems (three-phase, four-phase systems), insulation resistance in non-earthed DC supply systems (three-phase systems), adjustable sensitivity range: 1 - 100 kΩ, 2 - 200 kΩ, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC , Rated operating voltage for the supply system being monitored: 0 - 400 V AC, 0 - 600 V DC, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 22.5 mm, Standards: IEC/EN 60255-6,