Technical Information

Toote seisukord Uus
Tootja nimi HVI Conductor D 23mm Cu w. support. tube L 3200mm a. air-term. rod L 2
Bränd Dehn
Kategooriad Lightning Protection Components
Päritoluriik* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmoneeritud süsteemi kood 8538 9099 00
Juhi ristlõige 19 mm²
Juhi läbimõõt 5 mm
Juhi materjal Vask
Juhi kategooria Klass 1 = massiivne
Mantli materjal XLPE (VPE)

Pakendamise üksikasjad

Pakkimistase 1 4013364241244, 4013364241244

Muud tehnilised andmed

Värvus Hall
Pinnatöötlus Töötlemata
Mass/kaal 66.6 kg/100 m
Sobib kasutamiseks plahvatusohtlikus EX-keskkonnas Yes
Kiudude arv 1
Kõrgepingeisolatsiooniga mudel Yes
Isolatsiooni materjal PE
Suurim ekvivalentne eralduskaugus (õhus) 0.75 m
Suurim ekvivalentne eralduskaugus (tahkes ehitusmaterjalis) 1.5 m
Outer diameter incl. sheat/cover 23 mm
Suurim tõmbekoormus 950 N

Allalaadimised

Kirjeldus

HVI Conductor (high-voltage-resistant, insulated down conductor) in a supporting tube, to maintain the separation distance from electrically conductive parts according to IEC 62305-3, in order to prevent dangerous flashover between external lightning protection system components and indoor conductive parts (electrical installation, piping, etc.). In order to avoid creeping discharge, the HVI Conductor has a special outer sheath which makes it possible to discharge high lightning impulse voltages to a reference potential. HVI Conductor (grey), with sealing end and EB spring element inside the supporting tube (length 3200 mm) with air-termination rod (D22 / 16 / 10 mm length 2500 mm), with head piece, EB connection element and earth connection element. Equivalent separation distance s ≤ 075 cm (in air), s ≤ 150 cm (solid building material).