fan coil act. KNX DRA image 1

fan coil act. KNX DRA

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
271,43 €
Hind kehtib kuni 24.12.25
EAN: 4010337059387
MPN: 216300
Pakend: 1
Hinnanguline tarneaeg meie laos (umbes): 4-6 weeks

Technical Information

Toote seisukord Uus
Tootja nimi fan coil act. KNX DRA
Bränd Gira
Kategooriad Bus System Devices (KNX/Modbus)
Päritoluriik DE
Harmoneeritud süsteemi kood 8536 4900 00
Siinisüsteem KNX Yes
Siiniühendusega No
Siinisüsteem LON No
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline No

Pakendamise üksikasjad

Pakkimistase 1 4010337059387

Muud tehnilised andmed

Paigaldusviis DRA (DIN liistule)
Tunnusvool 0 A
Väljundvõimsus 0 W
Raadiosageduslik siinisüsteem No
Siinisüsteem Powernet No
Suurim lülitusvõimsus 0 W
Suurim lülituskontaktide arv 4
Digitaalsisendite arv 0
Laius mooduli arvudes 4
Suurim lülitusvool 0 A
Muud siinisüsteemid Puudub
C-koormus No
Eri faaside ühendamine No
Lokaaljuhtimine/käsijuhtimine No
Kaitseaste (IP) IP20
LED näidikuga No
Laiendusmoodulitega No
Eemaldatav siini moodul No
Sisseehitatud paigalduskarbi vähim sügavus 0 mm
Max. switching power LED 0 W

Kirjeldus

Fan coil actuator for KNX DRA plus Features: Fan coil actuator for operation of ventilator convectors (fan coil units), implemented for room air conditioning. The actuator receives telegrams, for example from room temperature controllers, and converts corrected variable telegrams into equivalent fan speeds and valve positions. Connection of a ventilator convector with up to six ventilator gradations or connection of two ventilator convectors each with up to three fan speeds with double pipe systems. Manual actuation. Building site operation: Outputs can be operated manually without bus voltage with operating voltage only. Operating modes for heating or cooling mode, or combined heating cooling mode. Double tube or quadruple tube operation. Double tube system heats or cools via a shared water cycle. Quadruple tube system consists of separate flow and return for heating and cooling. Individual or hierarchic switching of fan speeds. Feedback, output indication, block function for each channel, level limitation. Behaviour after bus voltage failure or bus mains voltage failure and following an ETS programming process can be configured. Limit values can be set. Cyclical or event-oriented transmission. Free channels can be used for switching functions, e.g. for room lighting Notes : VDE approval in accordance with EN 60669-1, EN 60669-2-1. Installation on DIN top-hat rail.