Technical Information
| Toote seisukord |
Uus |
| Tootja nimi |
Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 65 A, RAC 240: 190 - 240 V 50/60 Hz, Screw terminals |
| Bränd |
EATON
|
| Kategooriad |
AC Power Contactors
|
| Päritoluriik |
RO |
| Harmoneeritud süsteemi kood |
8536 4900 00
|
| Tunnustalitlusvõimsus, AC-3, 400 V |
30 kW |
| Normaalselt avatud peakontaktide arv |
3 |
| Normaalselt suletud peakontaktide arv |
0 |
| Tunnus-talitlusvool Ie, AC-3, 400 V |
65 A |
| Juhtahelate tunnus-toitepinge, AC 50 Hz |
190-240 V |
| Juhtahelate tunnus-toitepinge, AC 60 Hz |
190-240 V |
| Juhtahelate tunnus-toitepinge, DC |
0 V |
| Peaahela ühendusviis |
Kruviühendus |
| Aktiveerimispinge liik |
AC |
Pakendamise üksikasjad
| Pakkimistase 1 |
4015081042869 |
Muud tehnilised andmed
| Sobib DIN paigalduspaneelidele |
No |
| Normaalselt avatud abikontaktide arv |
0 |
| Normaalselt suletud abikontaktide arv |
0 |
| Tunnus-talitlusvool Ie, AC-1, 400 V |
85 A |
| Nimitöövool AC-4, 400 V korral |
25 A |
| Tunnustalitlusvõimsus Ie, AC-4, 400 V |
12 kW |
| Tunnustalitlusvõimsus (NEMA) |
37 kW |
Kirjeldus
Contactor, Application: Contactors for Semiconductor Industries acc. to SEMI F47, Contactors up to 150 A with electronic actuation, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Contactors suitable for semi-conductor industry according to SEMI F47., Contactors hum-free , suitable for building services automation., Operating mechanism adjustable from 50 Hz to 400 Hz., Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 65 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 98 A, enclosed: Ith= 72 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 200 A, enclosed: Ith= 180 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 20 kW, 380 V 400 V: P= 30 kW, 660 V 690 V: P= 35 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 7 kW , 380 V 400 V: P= 12 kW, 660 V 690 V: P= 17 kW, Instructions: Contacts to EN 50 012., built-in suppressor circuit'