Analog monitoring relay, resistance monitoring from 2 to 200 kohm
Laos: Ei
Hankija laovaru: Jah
Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
51,76 €
tk kohta
Hind kehtib kuni 24.12.25
Hinnanguline tarneaeg meie laos (umbes):
4-6 weeks
Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Analog monitoring relay, resistance monitoring from 2 to 200 kohm |
Bränd |
Siemens
|
Kategooriad |
Monitoring Relays
|
Päritoluriik |
CZ |
Harmoneeritud süsteemi kood |
8536 4190 00
|
Võimalik on kaskaadlülitus |
No |
Elektroodide sisendite hulk |
1 |
Reaktsioonitundlikkuse seadistamisega |
Yes |
Elektriühenduse liik |
Kruviühendus |
Mõõtmiste füüsikaline põhimõte |
Muul viisil |
Normaalselt suletud kontaktide arv |
0 |
Pakendamise üksikasjad
Pakkimistase 1 |
4011209665293 |
Muud tehnilised andmed
Laius |
22.5 mm |
Kõrgus |
92 mm |
Sügavus |
91 mm |
Eemaldatavate klambritega |
Yes |
Juhtahelate tunnus-toitepinge, AC 50 Hz |
24 V |
Juhtahelate tunnus-toitepinge, AC 60 Hz |
24 V |
Juhtahelate tunnus-toitepinge, DC |
24 V |
Suurim lubatud väljalülitusviivitus |
10 s |
Minimaalne seadistatav väljalülitusviivitus |
0.5 s |
Suurim lubatav viivitusaeg rakendumisel |
10 s |
Vähim seadistatav viivitusaeg rakendumisel |
0.5 s |
Aktiveerimispinge liik |
AC/DC |
Normaalselt avatud kontaktide arv |
0 |
Ümberlülituskontaktide arv |
1 |
Kirjeldus
Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm 0vershoot and undershoot Supply voltage 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit 2-step or 1-step control Tripping delay 0.5 to 10 s 1 change-over contact screw terminal Successor product for 3UG3501-1AC20 Level monitoring relay with analog setting SIRIUS 3UG4 for level monitoring of conductive fluids to protect against overflow, dry running or leakage.
Worldwide use thanks to wide voltage supply range and international certificates. Device replacement possible without rewiring, thanks to removable terminals Can be flexibly adapted to various conductive liquids through analog setting of the sensitivity. Upstream or downstream function is selectable By means of the adjustable tripping delay time, it is also possible to compensate for shaft movements. Other resistance sensors can also be connected, e.g. suitable photoresistors, temperature sensors, position encoders based on resistors etc.
In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection.
Available accessories include individually shortenable two-pole and 3-pole wire electrodes for easy mounting from above/below, as well as bow electrodes for installation from the side to allow higher filling levels and minimal space requirements. Additional accessories, such as unit labeling plates, push-in lugs and cover caps, are standardized for all relays.
SIRIUS relays - one range for every application.