Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
4MX656 492 7x2.5 SI image 1
4MX656 492 7x2.5 SI image 2
4MX656 492 7x2.5 SI image 3
4MX656 492 7x2.5 SI image 4
4MX656 492 7x2.5 SI thumbnail 1
4MX656 492 7x2.5 SI thumbnail 2
4MX656 492 7x2.5 SI thumbnail 3
4MX656 492 7x2.5 SI thumbnail 4

4MX656 492 7x2.5 SI

Müüja laos
Hind (ilma KM-ta):
55,39 €
Hind kehtib kuni 24.12.25
Jaga kasti: 10,00 €
EAN: 4030732584017
MPN: 4030732584017
Pakend: 1
Hinnanguline tarneaeg meie laos (umbes): 3-4 weeks

Technical Information

Toote seisukord Uus
Tootja nimi 4MX656 492 7x2.5 SI
Bränd PHILIPS
Kategooriad Rattatulede tarvikud
Päritoluriik NL
Harmoneeritud süsteemi kood 9405 9900 00
Kaitseklass I
Värvus Hõbedane
Laius 83 mm
Mudel Kaksikmooduli pikkus
Kõrgus 57.4 mm
Luminofoorlampide võimsus 49 W
Koos juhtmestusega Yes
Kaabli soonte arv 7
Sisseehitatud elektromehaaniline ballast No
Pikkus 2958 mm
Materjal Teras
Elektriline ühendus pistikusüsteemiga Yes
Kaabli soonte ristlõige 2.5 mm²
Elektriühikute muudetav vahekaugus No
Sobib kaablikanalile No
Kaitseaste (IP) IP20
Koos kaablirenniga No

Pakendamise üksikasjad

Pakkimistase 1 4030732584017

Allalaadimised

Kirjeldus

The trunking fulfils two functions: first, it provides a sturdy in-line mounting rail on which to fix the electrical units, and second, it provides a housing for the electrical cables that bring power to the units. All the light-line sections are made of hot-dip galvanized steel with a white or silver finish. They are available in dedicated TL5 lengths of 1, 2 and 3 electrical units 49 W (35/80 W) and 54 W (28 W). A flat ribbon cable (5 or 7 wires) or two flat ribbon cables (2 x 5 or 2 x 7 wires) are integrated in the trunking and guarantee (in combination with an integrated phase selection switch and contact blocks) safe and correct cabling. The 7-wire cable is used to integrate light regulation or emergency lighting for those electrical units that are equipped with emergency battery packs. Double wiring (2 x 5 or 2 x 7 wires) is needed to provide a completely separate mains supply to the electrical units. Double wiring is mostly used for emergency lighting by central emergency batteries or separate switching. Hence, no extra contact blocks or wiring are required. For suspended light lines, the light-line sections are connected using the integrated electrical connector and a sturdy external mechanical coupling piece (accessory). Surface-mounted light lines use the same integrated electrical connector and an internal coupler (accessory). On the upper part of the light-line section, special knock-out openings enable cable entry wherever needed. The trunking is available with a complete range of interchangeable components that optimize flexibility. The outstanding stability of the sections and coupling pieces allows suspension intervals of 3.4 to 5 m. The basic accessories of Maxos TL-D trunkings can also be used for the TL5 trunkings.