Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Earth-fault release, 30mA, 4p, bottom image 1
Earth-fault release, 30mA, 4p, bottom image 2
Earth-fault release, 30mA, 4p, bottom image 3
Earth-fault release, 30mA, 4p, bottom image 4
Earth-fault release, 30mA, 4p, bottom thumbnail 1
Earth-fault release, 30mA, 4p, bottom thumbnail 2
Earth-fault release, 30mA, 4p, bottom thumbnail 3
Earth-fault release, 30mA, 4p, bottom thumbnail 4

Earth-fault release, 30mA, 4p, bottom

Order only
Price (excl. VAT):
391,40 €
This price is valid until 24.12.25
EAN: 4015081044221
MPN: 104612
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name Earth-fault release, 30mA, 4p, bottom
Brand EATON
Categories Trip & Release Units
Country of origin* CZ
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8538 9099 00
Rated fault current 0.03 A
Rated control supply voltage at AC 50 Hz 200-415 V
Rated control supply voltage at AC 60 Hz 200-415 V
Rated control supply voltage at DC 0 V
Max. rated operation voltage Ue 415 V

Packing details

Packing level 1 4015081044221

Other Technical data

Delay adjustable No
Max. power on-delay time 30 ms

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for NZM1-4, N1-4