Register to unlock your exclusive B2B prices and start shopping. Sign up now!
DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M image 1
DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M image 2
DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M thumbnail 1
DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M thumbnail 2

DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
631,93 €
This price is valid until 24.12.25
EAN: 4547648096737
MPN: DRT2-AD04H
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M
Brand Omron
Categories Industrial Fieldbus Modules
Country of origin NL
Harmonized System Code 8471 6070 00
Suitable for safety functions No
Number of analogue inputs 4
Number of analogue outputs 0
Voltage type of supply voltage DC
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces USB 0
Supporting protocol for TCP/IP No
Supporting protocol for Modbus No
Type of electric connection Screw connection
Degree of protection (IP) IP20
Number of interfaces PROFINET 0
Supporting protocol for EtherNet/IP No
Supporting protocol for PROFINET IO No
Supply voltage DC 20.4-26.4 V
SIL according to IEC 61508 None

Packing details

Packing level 1 4547648096737, 4547648096737

Other Technical data

Width 115 mm
Height 50 mm
Depth 49.7 mm
Supporting protocol for LON No
Number of HW-interfaces RS-422 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 1
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
Input, current Yes
Input, voltage No
Input, resistor No
Input, resistance thermometer No
Input, thermocouple No
Input signal, configurable Yes
Output, current No
Output, voltage No
Output signal configurable No
Resolution of the analogue inputs 15 Bit
Rail mounting possible Yes
Explosion safety category for gas None
Explosion safety category for dust None
Fieldbus connection over separate bus coupler possible No
System accessory No
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Number of HW-interfaces Wireless 0
Front built-in possible No
Rack-assembly possible No
Wall mounting/direct mounting No
Radio standard Bluetooth No
Radio standard Wi-Fi 802.11 No
IO link master No
Performance level according to EN ISO 13849-1 Level a
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Analogue inputs configurable Yes
Analogue outputs configurable No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
Degree of protection (NEMA) Other

Downloads

Description

DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to 10 V, -10 to 10 V, isolated, resolution 1:30000