| Item condition | New |
| Manufacture name | Variable frequency drive DG1-34061FB-C21C 30kW 61A 400V 3-phase IP21 |
| Brand | EATON |
| Categories |
Frequenzumrichter bis 1 kV
|
| Country of origin* | CN |
| * The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager. | |
| ETIM | EC001857 |
| Mains voltage | 380-500 V |
| Mains frequency | 50/60 Hz |
| Number of phases input | 3 |
| Relative symmetric net voltage tolerance | 10 % |
| Relative symmetric net frequency tolerance | 10 % |
| Packing level 1 | 4015081710904 |
| Width | 237.7 mm |
| Height | 630 mm |
| Depth | 294 mm |
| With control element | Yes |
| Number of digital inputs | 8 |
| Number of digital outputs | 1 |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 2 |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | Yes |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | Yes |
| Degree of protection (IP) | IP21 |
| With PC connection | Yes |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| 4-quadrant operation possible | Yes |
| Number of interfaces PROFINET | 0 |
| Type of converter | U converter |
| Number of phases output | 3 |
| Integrated breaking resistance | Yes |
| Application in industrial area permitted | Yes |
| Application in domestic- and commercial area permitted | Yes |
| Max. output frequency | 400 Hz |
| Max. output at linear load at rated output voltage | 30 kW |
| Max. output at quadratic load at rated output voltage | 37 kW |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | Yes |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Max. output voltage | 500 V |
| Nominal output current I2N | 61 A |
| Supporting protocol for BACnet | Yes |
| Degree of protection (NEMA) | 1 |
Frequenzumrichter, Typkenner: DG1, Bemessungsbetriebsspannung: Ue = 400 V AC, 3-phasig, 480 V AC, 3-phasig, 500 V AC, 3-phasig, Ausgangsspannung bei Ue: U2 = 400 V AC, 3-phasig, 480 V AC, 3-phasig, 500 V AC, 3-phasig, Netzspannung (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Bemessungsbetriebsstrom bei 150 % Überlast: Ie = 61 A, Hinweis: Bemessungsbetriebsstrom bei einer Schaltfrequenz von 1 - 10 kHz und einer Umgebungstemperatur von +50 °C für 150 % Überlast und +40 °C für 110 % Überlast, Bemessungsbetriebsstrom bei 110 % Überlast: Ie = 72 A, Hinweis: Überlastzyklus für 60 s alle 600 s, Zugeordnete Motorleistung Hinweis: für normale vierpolige, innen- und außenbelüftete Drehstrom-Asynchronmotoren mit 1500 min-1 bei 50 Hz bzw. 1800 min-1 bei 60 Hz, Überlastzyklus für 60 s alle 600 s, bei 400 V, 50 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 30 kW, 110 % Überlast: P = 37 kW, 150 % Überlast: IM = 55.2 A, 110 % Überlast: IM = 68 A, Zugeordnete Motorleistung Hinweis: bei 500 V, 50 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 37 kW, 110 % Überlast: P = 45 kW, 150 % Überlast: IM = 54 A, 110 % Überlast: IM = 65 A, Zugeordnete Motorleistung Hinweis: bei 480 V, 60 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 40 HP, 110 % Überlast: P = 50 HP, Zugeordnete Motorleistung 150 % Überlast: IM = 52 A, 110 % Überlast: IM = 65 A, Schutzart: IP21/NEMA1, Schnittstelle/Feldbus (eingebaut): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Feldbusanschaltung (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Ausstattung: Funkentstörfilter, zusätzlicher Platinenschutz, mehrzeiliges Grafik-Display, Brems-Chopper, Zwischenkreisdrossel, Baugröße: FS4, Normen und Bestimmungen: Allgemeine Anforderungen: IEC/EN 61800-2, EMV-Anforderungen: IEC/EN 61800-3, Anforderungen an die Sicherheit: IEC/EN 61800-5, IEC/EN 60950-1: SELF