Technical Information
| Item condition |
New |
| Manufacture name |
DA1-32011FB-A20C Variable frequency drive, 230 V AC, 3-phase, 10.5 A, 2.2 kW, IP20/NEMA 0, Radio interference suppression filter, 7-digital display assembly |
| Brand |
EATON
|
| Categories |
Frequenzumrichter bis 1 kV
|
| Country of origin* |
GB |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| ETIM |
EC001857
|
| Mains voltage |
200-240 V |
| Mains frequency |
50/60 Hz |
| Number of phases input |
3 |
| Relative symmetric net voltage tolerance |
10 % |
| Relative symmetric net frequency tolerance |
10 % |
Packing details
| Packing level 1 |
4015081655786 |
Other Technical data
| Width |
107 mm |
| Height |
231 mm |
| Depth |
186 mm |
| With control element |
Yes |
| Number of digital inputs |
5 |
| Number of digital outputs |
2 |
| Number of analogue inputs |
2 |
| Number of analogue outputs |
2 |
| Supporting protocol for LON |
No |
| Number of HW-interfaces industrial Ethernet |
0 |
| Number of HW-interfaces RS-232 |
0 |
| Number of HW-interfaces RS-422 |
0 |
| Number of HW-interfaces RS-485 |
1 |
| Number of HW-interfaces serial TTY |
0 |
| Number of HW-interfaces USB |
0 |
| Number of HW-interfaces parallel |
0 |
| Number of HW-interfaces other |
0 |
| With optical interface |
No |
| Supporting protocol for TCP/IP |
Yes |
| Supporting protocol for ASI |
No |
| Supporting protocol for PROFIBUS |
Yes |
| Supporting protocol for CAN |
Yes |
| Supporting protocol for INTERBUS |
No |
| Supporting protocol for KNX |
No |
| Supporting protocol for Modbus |
Yes |
| Supporting protocol for Data-Highway |
No |
| Supporting protocol for DeviceNet |
Yes |
| Supporting protocol for SUCONET |
No |
| Supporting protocol for other bus systems |
Yes |
| Degree of protection (IP) |
IP20 |
| With PC connection |
Yes |
| Supporting protocol for SERCOS |
No |
| Supporting protocol for INTERBUS-Safety |
No |
| 4-quadrant operation possible |
Yes |
| Number of interfaces PROFINET |
0 |
| Type of converter |
U converter |
| Number of phases output |
3 |
| Integrated breaking resistance |
Yes |
| Application in industrial area permitted |
Yes |
| Application in domestic- and commercial area permitted |
Yes |
| Max. output frequency |
500 Hz |
| Max. output at linear load at rated output voltage |
2.2 kW |
| Max. output at quadratic load at rated output voltage |
2.2 kW |
| Supporting protocol for AS-Interface Safety at Work |
No |
| Supporting protocol for DeviceNet Safety |
No |
| Supporting protocol for EtherNet/IP |
Yes |
| Supporting protocol for Foundation Fieldbus |
No |
| Supporting protocol for PROFINET CBA |
No |
| Supporting protocol for PROFINET IO |
Yes |
| Supporting protocol for PROFIsafe |
No |
| Supporting protocol for SafetyBUS p |
No |
| Max. output voltage |
250 V |
| Nominal output current I2N |
10.5 A |
| Supporting protocol for BACnet |
No |
| Degree of protection (NEMA) |
Other |
Description
Frequenzumrichter, Typkenner: DA1, Bemessungsbetriebsspannung: Ue = 230 V AC, 3-phasig, 240 V AC, 3-phasig, Ausgangsspannung bei Ue: U2 = 230 V AC, 3-phasig, 240 V AC, 3-phasig, Netzspannung (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Bemessungsbetriebsstrom bei 150 % Überlast: Ie = 10.5 A, Hinweis: Bemessungsbetriebsstrom bei einer Schaltfrequenz von 16 kHz und einer Umgebungstemperatur von +50 °C, Hinweis: Überlastzyklus für 60 s alle 600 s, Zugeordnete Motorleistung Hinweis: für normale vierpolige, innen- und außenbelüftete Drehstrom-Asynchronmotoren mit 1500 min-1 bei 50 Hz bzw. 1800 min-1 bei 60 Hz, Überlastzyklus für 60 s alle 600 s, bei 230 V, 50 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 2.2 kW, 150 % Überlast: IM = 8.7 A, Zugeordnete Motorleistung Hinweis: bei 220 - 240 V, 60 Hz, Zugeordnete Motorleistung 150 % Überlast: P = 3 HP, Zugeordnete Motorleistung 150 % Überlast: IM = 9.6 A, Schutzart: IP20/NEMA 0, Schnittstelle/Feldbus (eingebaut): OP-Bus (RS485)/Modbus RTU, CANopen®, Feldbusanschaltung (optional): Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP, EtherCAT, SmartWire-DT, Ausstattung: Funkentstörfilter, Brems-Chopper, zusätzlicher Platinenschutz, 7-Segment-Anzeige, Baugröße: FS2, Normen und Bestimmungen: Allgemeine Anforderungen: IEC/EN 61800-2, EMV-Anforderungen: IEC/EN 61800-3, Anforderungen an die Sicherheit: IEC/EN 61800-5-1