UA50-30-00RA-85 Kondensatorschütz 380-400V 50Hz / 400-415V 60Hz

Nur auf bestellung
EAN: 3471522303851
MPN: 1SBL351024R8500
Karton: 1
Nettopreis
122,03 €
pro Stück
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 4-6 weeks
Preis gültig bis 31.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername UA50-30-00RA 380-400V 50Hz / 400-415V 60Hz Contactor
Marke ABB
Kategorien Kondensatorschütze
Code des Harmonisierten Systems 8536 4900 00
ETIM EC001079
Bemessungssteuerspeisespannung bei AC 50 Hz 380-400 V
Bemessungssteuerspeisespannung bei AC 60 Hz 400-415 V
Spannungsart für Betätigung AC

Verpackungsdetails

Verpackungsstufe 1 3471522303851
Verpackungsstufe 2 3471522303851

Weitere technische Daten

Anzahl Schließerkontakte als Hauptkontakt 3
Anzahl Öffnerkontakte als Hauptkontakt 0
Anzahl Hilfskontakte als Schließer 0
Anzahl Hilfskontakte als Öffner 0
Elektrische Anschlussart des Hauptstromkreises Schraubanschluss
Nenn-Jalousieleistung bei 400 V, 50 Hz 40 kvar

Downloads

Beschreibung

The UA50-30-00RA 380-400V 50Hz / 400-415V 60Hz is a 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles: 3 main poles - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.