Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
MD01 image 1
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor image 2
MD01 image 3
MD01 image 4
MD01 image 5
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor image 6
MD01 thumbnail 1
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor thumbnail 6

UA16-30-10RA-85 Kondensatorschütz 380-400V 50Hz / 400-415V 60Hz

Nur auf bestellung
EAN: 3471522300850
MPN: 1SBL181024R8510
Karton: 1
Nettopreis
48,55 €
pro Stück
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 4-6 weeks
Preis gültig bis 01.01.99 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor
Marke ABB
Kategorien Kondensatorschütze
Code des Harmonisierten Systems 8536 4900 00
ETIM EC001079
Bemessungssteuerspeisespannung bei AC 50 Hz 380-400 V
Bemessungssteuerspeisespannung bei AC 60 Hz 400-415 V
Spannungsart für Betätigung AC

Verpackungsdetails

Verpackungsstufe 1 3471522300850
Verpackungsstufe 2 3471522300850

Weitere technische Daten

Anzahl Schließerkontakte als Hauptkontakt 3
Anzahl Öffnerkontakte als Hauptkontakt 0
Anzahl Hilfskontakte als Schließer 1
Anzahl Hilfskontakte als Öffner 0
Elektrische Anschlussart des Hauptstromkreises Schraubanschluss
Nenn-Jalousieleistung bei 400 V, 50 Hz 12.5 kvar

Downloads

Beschreibung

The UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz is a 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.