Technische Informationen
| Artikelzustand |
Neu |
| Herstellername |
Switch actuator REG-K/2x230/16 w. manual mode and current detection, light grey |
| Marke |
Schneider Electric
|
| Kategorien |
KNX- & Modbus-Geräte
|
| Ursprungsland* |
DE |
|
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren.
Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
|
| Code des Harmonisierten Systems |
8537 1098 00
|
| ETIM |
EC001097
|
| KNX-Bussystem |
Ja |
| Mit Buskommunikation |
Ja |
| LON-Bussystem |
Nein |
| KNX-Funk-Bussystem |
Nein |
| Bidirektionaler Funk |
Nein |
Verpackungsdetails
| Verpackungsstufe 1 |
3606485100050 |
| Verpackungsstufe 2 |
3606485100058 |
Weitere technische Daten
| Befestigungsart |
DRA (DIN-Schienen-Adapter) |
| Bemessungsstrom |
16 A |
| Ausgangsleistung |
3600 W |
| Bemessungsbetriebsspannung |
230 V |
| Funk-Bussystem |
Nein |
| Powernet-Bussystem |
Nein |
| Max. Schaltleistung |
3600 W |
| Max. Anzahl Schaltkontakte |
2 |
| Anzahl Digitaleingänge |
0 |
| Breite in Teilungseinheiten |
2.5 |
| Max. Schaltstrom |
16 A |
| Geeignet für C-Last |
Ja |
| Anschluss unterschiedlicher Phasen möglich |
Ja |
| Lokale Bedienung/Handbedienung |
Ja |
| Schutzart (IP) |
IP20 |
| Mit LED-Anzeige |
Nein |
| Modular erweiterbar |
Nein |
| Busmodul abnehmbar |
Nein |
| Min. Tiefe der Unterputzdose |
0 mm |
| Max. LED-Leistungsanzeige |
0 W |
Downloads
Beschreibung
For independent switching of loads via make contacts. The actuator has integrated current detection that measures the load current on each channel. All 230 V switch outputs can be operated with manual switches. With integrated bus coupling unit. A green LED indicates that the device is ready for operation once the application has been loaded. The load is connected with screw terminals. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Operation as break contact or make contact. Staircase lighting function with/without manual OFF function and switch-off warning. Delay functions. Scenes. Logic function. Blocking or priority control. Feedback function. Status. Central function with delay. Parameterisation for bus voltage failure and recovery. Behaviour for download. Current detection function: Behaviour when value exceeds/falls short of the threshold value. Energy, operating and switch on counter with limit value monitoring. Flash function. Nominal voltage: 230 V AC, 50-60 Hz. DC 12-24 V ±10%, 0.1-16 A. For each switching contact: Switching current: 16 A, cos Phi 0.6. AC1 operation: max. 16 A. AC3 operation: max. 10 A. AC5 operation: max. 16 A. DC current switching capacity: max. 16 A/ 24 V DC. Output life endurance: Mechanical: