Register to unlock your exclusive B2B prices and start shopping. Sign up now!
S801S-K80-R High Performance MCB image 1
MD99 image 2
S801S-K80-R High Performance MCB image 3
S801S-K80-R High Performance MCB thumbnail 1
MD99 thumbnail 2
S801S-K80-R High Performance MCB thumbnail 3

S801S-K80-R Hochleist.-Sicherungsautomat 80A,K,400VAC=Icu 50kA,690VAC=Icu6kA,1P,

Order only
Price (excl. VAT):
96,76 € per pcs
This price is valid until next price list or while stock lasts
EAN: 7612271207571
MPN: 2CCS861002R0627
Box: 1
Estimate delivery time to our warehouse: 4-6 weeks

Technical Information

Item condition New
Manufacture name S801S-K80-R High Performance MCB
Brand ABB
Categories Leitungsschutzschalter 80 A
Harmonized System Code 8536 2090 00
ETIM EC000042
Rated current 80 A
Rated voltage 230 V
Release characteristic K
Width in number of modular spacings 1
Number of poles (total) 1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V 25 kA

Packing details

Packing level 1 7612271207571

Other Technical data

Voltage type AC/DC
Built-in depth 82,5 mm
Frequency 50-60 Hz
Rated insulation voltage Ui 690 V
Current limiting class 3
Over voltage category 4
Pollution degree 3
Explosion-proof FALSE
Degree of protection (IP) IP20
Number of protected poles 1
Concurrently switching neutral conductor FALSE
Connectable conductor cross section solid-core 0-50 mm²
Connectable conductor cross section multi-wired 0-70 mm²
Ambient temperature during operating -25-60 °C
Flush-mounted installation FALSE
Additional equipment possible TRUE
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V 25 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V 50 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V 4,5 kA
Rated impulse withstand voltage Uimp 8 kV

Downloads

Description

The S801S-K80-R is a 1-pole High Performance Circuit breaker with K-Characteristic, with ring tongue terminal and a rated current of 80 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S801S-K80-R complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S801S-K80-R more comfortable. Due to the fast arc extinction of S801S-K80-R your application will be secured.