Technical Information
| Item condition |
New |
| Manufacture name |
S203MT-C25NA Miniature Circuit Breaker - 3+NP - C - 25 A |
| Brand |
ABB
|
| Categories |
Leitungsschutzschalter 25 A
|
| Harmonized System Code |
8536 2010 00
|
| ETIM |
EC000042
|
| Rated current |
25 A |
| Rated voltage |
400 V |
| Release characteristic |
C |
| Width in number of modular spacings |
4 |
| Number of poles (total) |
4 |
Packing details
| Packing level 1 |
4016779828956 |
Other Technical data
| Voltage type |
AC |
| Built-in depth |
69 mm |
| Frequency |
50-60 Hz |
| Rated insulation voltage Ui |
440 V |
| Current limiting class |
3 |
| Over voltage category |
3 |
| Pollution degree |
3 |
| Explosion-proof |
No |
| Degree of protection (IP) |
IP20 |
| Number of protected poles |
3 |
| Concurrently switching neutral conductor |
Yes |
| Connectable conductor cross section solid-core |
0-25 mm² |
| Connectable conductor cross section multi-wired |
0-25 mm² |
| Ambient temperature during operating |
-25-55 °C |
| Flush-mounted installation |
No |
| Additional equipment possible |
Yes |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V |
10 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V |
15 kA |
| Rated impulse withstand voltage Uimp |
4 kV |
Downloads
Description
S200MT miniature circuit breakers are designed especially for traction and railway applications. Acc. NF F 16-101/102 the product range S200MT is classified with Exigence 3, enabling the use in all parts of the vehicle. They are current limiting and have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200MT comply with IEC/EN 60898-1 and IEC/EN 609 47-2. All system pro M compact accessories can be used.
Including the bottom-fitting auxiliary contact S2C-Hxx providing the possibility of 50% space saving and the creation of group signals.