Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 1
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 2
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 3
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 4
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 5
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA image 6
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 1
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 2
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 3
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 4
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 5
SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA thumbnail 6

Überspannungsableiter steckbar, 1p, 460VAC, 20kA

In vendor's stock
Price (excl. VAT):
30,73 €
This price is valid until next price list or while stock lasts
EAN: 4015081640676
MPN: 167608
Package: 1
Box: 2
Estimate delivery time to our warehouse: 4-6 weeks

Technical Information

Item condition New
Manufacture name SPCT2-460/1 Plug-in surge arresters, 1p, 460VAC, 20 kA
Brand EATON
Categories Überspannungsschutzgeräte (SPD)
Country of origin* RO
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 5080 00
ETIM EC000941
Voltage protection level 2.2 kV
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 460 V
Nominal voltage DC 0 V
Voltage protection level L-N 0 kV
Degree of protection (IP) IP20
Max. PV-voltage 0 V
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C-S No

Packing details

Packing level 1 4015081640676
Packing level 2 9008790474811
Packing level 3 9008790474828

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 1
Construction size 1 modular spacing
Max. continuous voltage AC 460 V
Category type 2 Yes
Signalling at the device Optic
Max. continuous voltage DC 0 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
System configuration TN-C No
System configuration TN-S Yes
System configuration TT No
System configuration other Yes
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 125 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Description

Zum Schutz von Verbraucheranlagen gegen transiente Überspannungen hervorgerufen durch indirekte Blitzschläge und Schalthandlungen, Prüfklasse II nach IEC 61643-1+A1, SPD-type T2 nach EN 61643-11, Hilfsschalter SPC-S-HK für Fernmeldung anbaubar, Verschienbar mit allen Xtra Combinations Schaltgeräten hervorgerufen durch indirekte Blitzschläge und Schalthandlungen, Prüfklasse II nach IEC 61643-1+A1, SPD-type T2 nach EN 61643-11, Hilfsschalter SPC-S-HK für Fernmeldung anbaubar, Verschienbar mit allen Xtra Combinations Schaltgeräten