Register to unlock your exclusive B2B prices and start shopping. Sign up now!
OVR T2 1N 40-440 P TS QS Surge Protective Device image 1
OVR T2 1N 40-440 P TS QS Surge Protective Device image 2
OVR T2 1N 40-440 P TS QS Surge Protective Device thumbnail 1
OVR T2 1N 40-440 P TS QS Surge Protective Device thumbnail 2

OVR T2 1N 40-440 P TS QS Überspannungsableiter Typ 2, TT- und TN,

Order only
Price (excl. VAT):
67,27 €
This price is valid until next price list or while stock lasts
EAN: 3660308524577
MPN: 2CTB803972R1400
Package: 1
Box: 5
Estimate delivery time to our warehouse: 6-8 weeks

Technical Information

Item condition New
Manufacture name OVR T2 1N 40-440 P TS QS Surge Protective Device
Brand ABB
Categories Überspannungsschutzgeräte (SPD)
Harmonized System Code 8536 9095 00
ETIM EC000941
Voltage protection level 1.5 kV
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 230 V
Voltage protection level L-N 1.25 kV
Degree of protection (IP) IP20
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C-S Yes

Packing details

Packing level 1 3660308524577
Packing level 2 3660308524577

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 2 modular spacing
Max. continuous voltage AC 440 V
Category type 2 Yes
Signalling at the device Optic
Voltage protection level N-PE 1.4 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 16 mm²
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
Max. discharge surge current (8/20) 80 kA
Short-circuit breaking capacity (Isccr) 100 kA
Max. overcurrent protection device, parallel connection (fuse) 125 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 125 A
Leakage-current free Yes

Downloads

Description

Type 2 SPD’s are designed to discharge the currents generated by indirect lightning strikes causing induced or conducted overvoltages on the power distribution network. They are characterized by an 8/20μs waveform (Imax). Higher is the Imax, more powerful they are. They are installed in the main distribution switchboard but also in sub-distribution board. They have a low residual voltage Up often compatible with the withstand voltage of the equipment to protect. If this is not the case or the cable length to the equipment is longer than 10m, another level of coordination with OVR T2-T3, OVR T3 will be needed.