Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 1
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 2
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 3
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 4
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 5
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 6
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 7
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 8
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 9
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 10
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology image 11
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 1
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 2
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 3
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 4
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 5
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 6
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 7
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 8
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 9
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 10
NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology thumbnail 11

NZM2 PXR25 Leistungsschalter - integrierte Energiemessung Klasse 1, 63A, 4p, variabel, Erdschlussschutz und Zonenselektivität, Stecktechnik

Nur auf bestellung
EAN: 4015081926428
MPN: 192091
Verpackung: 1
Nettopreis
2 395,19 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 6 weeks
Dieser Preis gilt bis zur nächsten Preisliste oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername NZMS2-4-PX63/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 63A, 4p, variable, earth-fault protection and zone selectivity, plug-in technology
Marke EATON
Kategorien Leistungsschalter
Ursprungsland* RO
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 8536 2010 00
ETIM EC000228
Bemessungsdauerstrom Iu 63 A
Polzahl 4
Bemessungsspannung 690 V
Schutzart (IP) IP20
Mit Aus-Anzeige Nein
Bemessungsgrenzkurzschlussausschaltvermögen Icu bei 400 V, 50 Hz 70 kA
Integrierter Erdschlussschutz Ja
Gerätebauart Einbaugerät in Stecktechnik

Verpackungsdetails

Verpackungsstufe 1 4015081926428

Weitere technische Daten

Anzahl Hilfskontakte als Schließer 0
Anzahl Hilfskontakte als Öffner 0
Mit integriertem Unterspannungsauslöser Nein
Aktuelle Einstellung der Überlastauslösung 25-63 A
Anzahl Hilfskontakte als Wechsler 0
Anschlussposition des Hauptstromkreises Anschluss an separatem Chassisteil
Integrierter Motorantrieb Nein
Elektrische Anschlussart des Hauptstromkreises Sonstige
Art des Bedienelements Kipphebel
Einstellbereich der kurzzeitverzögerten Kurzschlussauslösung 2-10 A
Einstellbereich des unverzögerten Kurzschlussauslösers 2-18 A
Geeignet für DIN-Schienenmontage (Hutschiene) Nein
Motorantrieb optional Ja
DIN-Schienenmontage (Hutschiene) optional Nein
Komplettgerät mit Schutzeinheit Ja

Beschreibung

Die Leistungsschalter der Serie xEffect NZM…-PX…-TZ mit Power Expert Release (PXR) Auslöseelektronik decken mit nur vier kompakten Baugrößen Anwendungsfälle für den Vollbereichsschutz inklusive Erdschlussschutz ab und sind für den IEC-Markt geeignet. Die integrierte Energiemessfunktion liefert Ströme, Spannungen und Wirkenergie (kWh) mit Genauigkeitsklasse 1 nach IEC 61557-12. Zonenselektivität für erweiterten Schutz enthalten. Test-Funktion und Einstellungen über Mikro-USB-Schnittstelle direkt am Schalter. Die Montage ist immer flexibel durch modulare Funktionsgruppen und kann durch das umfangreiche Zubehörsortiment ergänzt werden. Effektivwertmessung und thermisches Gedächtnis.