Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 1
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 2
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 3
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 4
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 5
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 6
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 7
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 8
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 9
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 10
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity image 11
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 1
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 2
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 3
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 4
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 5
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 6
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 7
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 8
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 9
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 10
NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity thumbnail 11

NZM2 PXR25 Leistungsschalter - integrierte Energiemessung Klasse 1, 250A, 4p, variabel, Schraubanschluss, Erdschlussschutz und Zonenselektivität

Nur auf bestellung
EAN: 4015081927876
MPN: 192236
Verpackung: 1
Nettopreis
1 380,14 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 4-6 weeks
Preis gültig bis 24.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername NZMS2-4-PX250/VAR-TZ NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 250A, 4p, variable, Screw terminal, earth-fault protection and zone selectivity
Marke EATON
Kategorien Leistungsschalter
Ursprungsland* RO
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 8536 2090 00
ETIM EC000228
Bemessungsdauerstrom Iu 250 A
Polzahl 4
Bemessungsspannung 690 V
Schutzart (IP) IP20
Mit Aus-Anzeige No
Bemessungsgrenzkurzschlussausschaltvermögen Icu bei 400 V, 50 Hz 70 kA
Integrierter Erdschlussschutz Yes
Gerätebauart Einbaugerät mit fester Einbautechnik

Verpackungsdetails

Verpackungsstufe 1 4015081927876

Weitere technische Daten

Anzahl Hilfskontakte als Schließer 0
Anzahl Hilfskontakte als Öffner 0
Mit integriertem Unterspannungsauslöser No
Aktuelle Einstellung der Überlastauslösung 100-250 A
Anzahl Hilfskontakte als Wechsler 0
Anschlussposition des Hauptstromkreises Vorderseite
Integrierter Motorantrieb No
Elektrische Anschlussart des Hauptstromkreises Schraubanschluss
Art des Bedienelements Kipphebel
Einstellbereich der kurzzeitverzögerten Kurzschlussauslösung 2-10 A
Einstellbereich des unverzögerten Kurzschlussauslösers 2-12 A
Geeignet für DIN-Schienenmontage (Hutschiene) No
Motorantrieb optional Yes
DIN-Schienenmontage (Hutschiene) optional Yes
Komplettgerät mit Schutzeinheit Yes

Downloads

Beschreibung

Die Leistungsschalter der Serie xEffect NZM…-PX…-TZ mit Power Expert Release (PXR) Auslöseelektronik decken mit nur vier kompakten Baugrößen Anwendungsfälle für den Vollbereichsschutz inklusive Erdschlussschutz ab und sind für den IEC-Markt geeignet. Die integrierte Energiemessfunktion liefert Ströme, Spannungen und Wirkenergie (kWh) mit Genauigkeitsklasse 1 nach IEC 61557-12. Zonenselektivität für erweiterten Schutz enthalten. Test-Funktion und Einstellungen über Mikro-USB-Schnittstelle direkt am Schalter. Die Montage ist immer flexibel durch modulare Funktionsgruppen und kann durch das umfangreiche Zubehörsortiment ergänzt werden. Effektivwertmessung und thermisches Gedächtnis.