Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 1
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 2
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 3
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 4
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 5
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 6
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 7
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 8
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 9
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 10
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 11
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 1
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 2
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 3
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 4
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 5
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 6
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 7
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 8
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 9
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 10
NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 11

NZM2 PXR25 Leistungsschalter - integrierte Energiemessung Klasse 1, 160A, 4p, variabel, Erdschlussschutz und Zonenselektivität, Stecktechnik

Nur auf bestellung
EAN: 4015081926510
MPN: 192100
Verpackung: 1
Nettopreis
1 464,67 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 4-6 weeks
Preis gültig bis 24.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername NZMH2-4-PX160/VAR-TZ-SVE NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 160A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog
Marke EATON
Kategorien Leistungsschalter
Ursprungsland* RO
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 8536 2090 00
ETIM EC000228
Bemessungsdauerstrom Iu 160 A
Polzahl 4
Bemessungsspannung 690 V
Schutzart (IP) IP20
Mit Aus-Anzeige Nein
Bemessungsgrenzkurzschlussausschaltvermögen Icu bei 400 V, 50 Hz 150 kA
Integrierter Erdschlussschutz Ja
Gerätebauart Einbaugerät in Stecktechnik

Verpackungsdetails

Verpackungsstufe 1 4015081926510

Weitere technische Daten

Anzahl Hilfskontakte als Schließer 0
Anzahl Hilfskontakte als Öffner 0
Mit integriertem Unterspannungsauslöser Nein
Aktuelle Einstellung der Überlastauslösung 64-160 A
Anzahl Hilfskontakte als Wechsler 0
Anschlussposition des Hauptstromkreises Anschluss an separatem Chassisteil
Integrierter Motorantrieb Nein
Elektrische Anschlussart des Hauptstromkreises Sonstige
Art des Bedienelements Kipphebel
Einstellbereich der kurzzeitverzögerten Kurzschlussauslösung 2-10 A
Einstellbereich des unverzögerten Kurzschlussauslösers 2-18 A
Geeignet für DIN-Schienenmontage (Hutschiene) Nein
Motorantrieb optional Ja
DIN-Schienenmontage (Hutschiene) optional Nein
Komplettgerät mit Schutzeinheit Ja

Beschreibung

Die Leistungsschalter der Serie xEffect NZM…-PX…-TZ mit Power Expert Release (PXR) Auslöseelektronik decken mit nur vier kompakten Baugrößen Anwendungsfälle für den Vollbereichsschutz inklusive Erdschlussschutz ab und sind für den IEC-Markt geeignet. Die integrierte Energiemessfunktion liefert Ströme, Spannungen und Wirkenergie (kWh) mit Genauigkeitsklasse 1 nach IEC 61557-12. Zonenselektivität für erweiterten Schutz enthalten. Test-Funktion und Einstellungen über Mikro-USB-Schnittstelle direkt am Schalter. Die Montage ist immer flexibel durch modulare Funktionsgruppen und kann durch das umfangreiche Zubehörsortiment ergänzt werden. Effektivwertmessung und thermisches Gedächtnis.