Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 1
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 2
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 3
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 4
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 5
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 6
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 7
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 8
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 9
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 10
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 11
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 12
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 13
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 14
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 15
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 16
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 17
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 18
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 19
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 20
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 21
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 22
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 image 23
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 1
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 2
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 3
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 4
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 5
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 6
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 7
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 8
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 9
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 10
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 11
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 12
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 13
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 14
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 15
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 16
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 17
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 18
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 19
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 20
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 21
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 22
NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2 thumbnail 23

NH-Trenner 3P Rahmenklemme 95 - 300 mm²; Sammelschiene 60 mm; Sicherungsüberwachung Light; NH2

Nur auf bestellung
EAN: 4015081779956
MPN: 183068
Verpackung: 1
Nettopreis
378,14 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 4-6 weeks
Dieser Preis gilt bis zur nächsten Preisliste oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername NH fuse-switch 3p box terminal 95 - 300 mm², busbar 60 mm, light fuse monitoring, NH2
Marke EATON
Kategorien Sicherungslasttrennschalter
Ursprungsland* DE
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 8536 9010 00
ETIM EC001040
Bemessungsdauerstrom Iu 400 A
Polzahl 3
Schutzart (IP), Frontseite Sonstige
Für Sicherungen geeignet NH2
Ausführung als Hauptschalter Nein
Ausführung als Sicherheitsschalter Nein
Bemessungsbetriebsleistung bei AC-23, 400 V 0 kW
Max. Bemessungsbetriebsspannung Ue AC 690 V

Verpackungsdetails

Verpackungsstufe 1 4015081779956

Weitere technische Daten

Kabeleinführung Sonstige
Bedingter Bemessungskurzschlussstrom Iq 120 kA
Integrierter Motorantrieb Nein
Elektrische Anschlussart des Hauptstromkreises Rahmenklemme
Ausführung als Not-Aus-Einrichtung Nein
Art des Bedienelements Deckelgriff
Bemessungskurzzeitstromfestigkeit Icw 3 kA
Geeignet für Bodenmontage Nein
Für Frontmontage geeignet Nein
Für Sammelschienenmontage geeignet Ja
Mit Fehlsteckschutz Ja
Motorantrieb optional Nein
Position des Bedienelements Vorderseite
Mit Steckverbindern ausgestattet Nein

Beschreibung

NH-Sicherungs-Lasttrennschalter 3-polig mit Rahmenklemme 95 - 300 mm²; Sammelschiene 60 mm; Sicherungsüberwachung Light mit LED; für Sicherungseinsätze NH2; optional mit XNH-XLOCK und Vorhängeschloss abschliessbar; Kabelanschluss oben/unten in Sekundenschnelle umbaubar.