Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 1
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 2
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 3
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 4
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 5
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta image 6
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 1
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 2
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 3
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 4
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 5
Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta thumbnail 6

Multi MPPT PV-Überspannungsschutz, 1.000 V, Klasse 1 und 2 kombiniert

Order only
EAN: 9010653062998
MPN: EP-501957
Package: 1
No pricing modes available.

Technical Information

Item condition New
Manufacture name Multi MPPT PV-SPD, 1000V, class 1 and 2 combined tested with AUX conta
Brand EATON
Categories Überspannungsschutzgeräte (SPD)
Country of origin* SI
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 3090 00
ETIM EC000381
Mounting method DIN rail (top hat rail) 35 mm
Lightning impulse current (10/350 µs) 10 kA
Voltage protection level 3.8 kV
Nominal discharge surge current (8/20) 20 kA
Nominal voltage DC 1000 V
Category type 1 Yes
Voltage protection level L-N 3.8 kV
Max. continuous voltage DC 1000 V
Degree of protection (IP) IP20

Packing details

Packing level 1 9010653062998

Other Technical data

With remote signalling contact Yes
Number of conductors (without earthing) 4
Construction size 5 modular spacing
Suitable for outdoor use No
Exhausting No
Signalling at the device Optic
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
Voltage protection level (DC+ - DC-) 3.8 kV
Voltage protection level (DC+/DC- - PE) 3.8 kV
Specific energy (W/R) 6.25 kJ/Ohm
System configuration DC Yes
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No