Technische Informationen
| Artikelzustand |
Neu |
| Herstellername |
Wireless single-phase energy meter |
| Marke |
ELTAKO
|
| Kategorien |
KNX- & Modbus-Geräte
|
| Ursprungsland* |
CN |
|
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren.
Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
|
| Code des Harmonisierten Systems |
8526 9200 00
|
| ETIM |
EC001102
|
| Modell |
Sonstige |
| Anschlussart |
Gerade |
| S0-Impulsschnittstelle |
Nein |
| Genauigkeitsklasse |
1 |
Verpackungsdetails
| Verpackungsstufe 1 |
4010312311059, 4010312311059 |
| Verpackungsstufe 2 |
4010312311059 |
| Verpackungsstufe 3 |
4010312311059 |
Weitere technische Daten
| KNX-Bussystem |
Nein |
| Funk-Bussystem |
Ja |
| Powernet-Bussystem |
Nein |
| Tarifumschalter |
Nein |
| Blindleistung |
Nein |
| PTB-zugelassen |
Nein |
| Sonstige Bussysteme |
Nein |
| LON-Bussystem |
Nein |
| KNX-Funk-Bussystem |
Nein |
| Bidirektionaler Funk |
Nein |
Downloads
Beschreibung
Wireless single-phase energy meter, maximum current 65A. Only 0.5 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. This single-phase energy meter measures active energy by means of the current between input and output and transmits the current power and meter reading over the Eltako wireless network. Accuracy class B (1%). Evaluation and smart link via Smart Home-Controller. The internal power consumption of max. 0.5 watt active power is not metered. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1 phase conductor with a max. current up to 65A can be connected. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. If necessary, use spacer DS12. The inrush current is 40mA. The consumption is saved to a non-volatile memory and is immediately available again after a power failure. Wireless telegrams: A telegram is transmitted within 60 seconds if the power status changes by min. 10 percent. A change in meter reading is transmitted immediately. A full telegram comprising meter reading and power status is transmitted every 10 minutes. When the power supply is switched on, a teach-in telegram is sent to teach in the associated energy consumption indicator. If the L input and the L output were interchanged when hooked up, a normal rate (HT)/off-peak (NT) switchover telegram is transmitted to indicate the hook-up error.