Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
Noiseless impulse switch with integrated relay function with solid state relay image 1

Noiseless impulse switch with integrated relay function with solid state relay

Nur auf bestellung
EAN: 4010312109786
MPN: 61100003
Verpackung: 1
Nettopreis
39,91 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 2-4 weeks
Preis gültig bis 31.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername Noiseless impulse switch with integrated relay function with solid state relay
Marke ELTAKO
Kategorien Bistabile Relais
Ursprungsland* CN
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 8536 5080 00
ETIM EC000188
Befestigungsart Unterputzmontage (Putz)
Funktion Elektronisch mit Ausschaltverzögerung
Steuerspannung 1 230 V
Art der Steuerspannung 1 AC
Art der Versorgungsspannung AC
Versorgungsspannung 230 V
Bemessungsschaltstrom 2 A
Anzahl Kontakte als Schließer 1

Verpackungsdetails

Verpackungsstufe 1 4010312109786, 4010312109786
Verpackungsstufe 2 4010312109786
Verpackungsstufe 3 4010312109786

Weitere technische Daten

Einbautiefe 18 mm
Frequenz der Steuerspannung 1 50 Hz
Geeignet für Handbetrieb Nein
Max. Glühlampenlast 400 W
Max. Leuchtstofflampenlast 400 VA
Max. Leuchtstofflampenlast (parallel kompensiert) 400 VA
Anzahl Kontakte als Öffner 0
Anzahl Kontakte als Wechsler 0

Downloads

Beschreibung

Noiseless solid state relay not potential free. 230V LED lamps up to 400W, incandescent lamp load 400W, off delay impulse switch with switch-off early warning and pushbutton permanent light switchable. Standby loss 0,3 watt only. For installation. 45mm long, 45mm wide, 18mm deep. Supply, switching and control voltage 230V. Zero passage switching. In case of a power failure the system is disconnected in a preset sequence. In the ER function the relay switches back on when the power is restored and the control input is active. It is not permitted to apply a glow lamp current to the control input. With automatic electronic overtemperature switch-off. At a load of < 1W a GLE must be switched in parallel to the load. Use the top rotary switch to select the required function of this impulse switch: ER = switching relay. ESV = impulse switch. Possibly with off delay, then + pushbutton permanent light = ESV with pushbutton permanent light. + switch-off early warning = ESV with switch-off early warning. + pushbutton permanent light and switch-off early warning = ESV with pushbutton permanent light and switch-off early warning. The LED flashes when the rotary switch reaches a new setting range to assist you to find the require position with certainty. The LED lights up permanently when the relay is switched on. When the pushbutton permanent light is switched on , set the LED to permanent light by pressing the pushbutton for longer than 1 second. This is indicated by the LED flickering briefly. After 2 hours, the permanent light switches off automatically or it can be switched off previously by briefly pressing the pushbutton. If the switch-off early warning is switched on, the light starts to flicker approx. 30 seconds before time-out. This is repeated three times at decreasing time intervals. During the switch-off early warning, the light can be switched back on by briefly pressing the pushbutton. If both switch-off early warning and pushbutton permanent light are switched on, switch-off early warning is activated before automatic switch-off of the permanent light. The function ESV on the bottom rotary switch sets the off delay from 2 to 120 minutes. In setting infinite normal impulse switch function ES without off delay, without pushbutton permanent light and without switch-off early warning. In the ER function a switch-on wipe time can be set between 2 and 120 seconds. On expiry of the wipe time the relay switches off automatically. In setting infinite default relay function ER without wipe time.