Registrieren Sie sich, um Ihre exklusiven B2B-Preise freizuschalten und mit dem Einkauf zu beginnen. Jetzt registrieren!
RS485 bus wireless three-phase energy meter, MID approval image 1

RS485 bus wireless three-phase energy meter, MID approval

Nur auf bestellung
EAN: 4010312501450
MPN: 28305712
Verpackung: 1
Nettopreis
179,16 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 2-4 weeks
Preis gültig bis 31.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername RS485 bus wireless three-phase energy meter, MID approval
Marke ELTAKO
Kategorien Stromzähler & Energiemessgeräte
Ursprungsland* CN
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 9028 3019 00
ETIM EC001506
Befestigungsart DRA (DIN-Schienen-Adapter)
Breite 70 mm
Höhe 82 mm
Tiefe 58 mm
Frequenz 50 Hz
Max. Strom (Imax) 6 A
Breite in Teilungseinheiten 4
Schutzart (IP) IP20
Polart Vier Leiter
Nennspannung (Un) N-L 230 V
Bemessungsstrom (In) 5 A

Verpackungsdetails

Verpackungsstufe 1 4010312501450, 4010312501450
Verpackungsstufe 2 4010312501450

Weitere technische Daten

Modell Messwandler
Geeignet für Bezug
Anzeigeart Digital
Gesamtanzahl Stellen (Zähler) 7
Zählertyp Elektronisch
Schnittstellentyp RS-485
Energieart Wirkleistung
Tarifart Eintarif
Tarifsteuerung Extern
Auslösemechanismus Ja
Geeicht Ja
Zulassung Messgeräterichtlinie
Genauigkeitsklasse B
Art der Lastprofilmessung Nein
EEC40-Kennzeichnung Nein
Mit Sperrcode Nein
Nennspannung (Un) L-L 400 V

Downloads

Beschreibung

RS485 bus wireless three-phase energy meter with settable CT ratio and MID. Maximum current 3x5A. Standby loss 0.8W at L1 and only 0.5 W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. This three-phase energy meter measures active energy by means of the ­current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 5 A can be connected. The inrush current is 10mA. The terminals L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 10 times per kWh next to the display. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. The display then shows the total active energy, the active energy of the resettable memory as well as the instantaneous values of consumption, voltage and current per phase. The CT ratio can also be set. It is set to 5:5 at the factory and blocked with a bridge over the terminals which are marked with 'JUMPER'. To adjust the CT ratio to the installed transformer remove the bridge and reset the energy meter according to the operation manual. Then block it again with the bridge. Adjustable current transformer ratios: 5:5, 50:5, 100:5, 150:5, 200:5, 250:5, 300:5, 400:5, 500:5, 600:5, 750:5, 1000:5, 1250:5 and 1500:5. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. Important! Before working on the current transformers disconnect the voltage paths of the energy meters.