RS485 bus wireless three-phase energy meter, MID approval

Nur auf bestellung
EAN: 4010312501733
MPN: 28365715
Verpackung: 1
Nettopreis
162,79 €
pro Einheit
Mindestbestellmenge: 1
Lieferzeit zu unserem Lager: 2-4 weeks
Preis gültig bis 31.12.26 oder solange der Vorrat reicht

Technische Informationen

Artikelzustand Neu
Herstellername RS485 bus wireless three-phase energy meter, MID approval
Marke ELTAKO
Kategorien Stromzähler & Energiemessgeräte
Ursprungsland* CN
* Das tatsächliche Ursprungsland kann je nach Liefercharge variieren. Um das konkrete Ursprungsland zu bestätigen, wenden Sie sich bitte an Ihren Kundenbetreuer.
Code des Harmonisierten Systems 9028 3019 00
ETIM EC001506
Befestigungsart DRA (DIN-Schienen-Adapter)
Breite 70 mm
Höhe 82 mm
Tiefe 58 mm
Frequenz 50 Hz
Max. Strom (Imax) 80 A
Breite in Teilungseinheiten 4
Schutzart (IP) IP20
Polart Vier Leiter
Nennspannung (Un) N-L 230 V
Bemessungsstrom (In) 10 A

Verpackungsdetails

Verpackungsstufe 1 4010312501733, 4010312501733
Verpackungsstufe 2 4010312501733

Weitere technische Daten

Modell Direktmessung
Geeignet für Bezug
Anzeigeart Digital
Gesamtanzahl Stellen (Zähler) 7
Zählertyp Elektronisch
Schnittstellentyp RS-485
Energieart Wirkleistung
Tarifart Zweitarif
Tarifsteuerung Extern
Auslösemechanismus Ja
Geeicht Ja
Zulassung Messgeräterichtlinie
Impulsausgang Elektrisch
Genauigkeitsklasse B
Art der Lastprofilmessung Nein
EEC40-Kennzeichnung Nein
Mit Sperrcode Nein
Nennspannung (Un) L-L 400 V

Downloads

Beschreibung

RS485 bus wireless three-phase energy meter. Maximum current 3x80A. Standby loss 0.8W at L1 and only 0.5W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The terminals ‹L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 1000 times per kWh next to the display. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230 V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display.