Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
MD01 image 5
MD01 image 6
MD01 image 7
MD01 image 8
MD01 image 9
MD01 image 10
WF39KW14 Measurement and metering transformer board, Field width: 3, Rows: 0, 1350 mm x 750 mm x 160 mm, IP2XC image 11
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
MD01 thumbnail 6
MD01 thumbnail 7
MD01 thumbnail 8
MD01 thumbnail 9
MD01 thumbnail 10
WF39KW14 Measurement and metering transformer board, Field width: 3, Rows: 0, 1350 mm x 750 mm x 160 mm, IP2XC thumbnail 11

WF39KW14 M+W 9RE/3FB Komplettfeld, mit Zählerkreuz

Order only
Price (excl. VAT):
2 449,28 €
This price is valid until next price list or while stock lasts
EAN: 4011617560265
MPN: 2CPX056026R9999
Box: 1
Estimate delivery time to our warehouse: 4-6 weeks

Technical Information

Item condition New
Manufacture name WF39KW14 Measurement and metering transformer board, Field width: 3, Rows: 0, 1350 mm x 750 mm x 160 mm, IP2XC
Brand ABB
Categories Zählerkästen
Harmonized System Code 8537 1098 00
ETIM EC000263
With wiring Yes
Number of meter cabinets 1
Lower connection space With bus bar 5-pole
Degree of protection (IP) IP2XC
Main switch rated current 250 A

Packing details

Packing level 1 4011617560265

Other Technical data

Colour Grey
Width 750 mm
Model 1-story
Height 1350 mm
RAL-number 7035
With mounting plate No
Connection space 300 mm
Width in number of modular spacings 36
Number of TSG-panels 1
Number of distributor rows 0
Cover model Closed with prestamping

Description

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 200 A, Rated current of the assembly of switchgear and controlgear InA 200 A, in RAL 7035, dimensions in mm (H x W x D): 1350 x 750 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse switch disconnector NH1/250A, current transformer range CT mounting pad with CT rail 170 x 30 x 5 mm, parting point after the current transformer Switch disconnector 250 A / 4-pole, primary wiring L1-L3 Cu-Busbar 30 x 5 und 20 x 5, PE+N Cu-Busbar 20 x 5 mm, Accessible to Cu busbar, outgoing: terminals screws to fuse disconnetor and PE+N busbar, Connection N+PE (M8), Grid unit 9 GU, Overall height 5, panel width 3, Space units 324, covers out of Plastic, Quick sealable connection, RAL 7035