Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
MD01 image 5
MD01 image 6
KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC image 7
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
MD01 thumbnail 6
KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC thumbnail 7

KA4256Z Mess-u.Wandlerfeld H3/B3

Order only
Price (excl. VAT):
2 060,97 €
This price is valid until next price list or while stock lasts
EAN: 4011617350750
MPN: 2CPX035075R9999
Box: 1
Estimate delivery time to our warehouse: 4-6 weeks

Technical Information

Item condition New
Manufacture name KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC
Brand ABB
Categories Zählerkästen
Harmonized System Code 8537 1098 00
ETIM EC000263
With wiring Yes
Number of meter cabinets 1
Lower connection space With DIN rails (top hat rails)
Degree of protection (IP) IP2XC
Main switch rated current 250 A

Packing details

Packing level 1 4011617350750

Other Technical data

Colour Grey
Width 750 mm
Model 1-story
Height 1050 mm
RAL-number 7035
With mounting plate No
Connection space 300 mm
Width in number of modular spacings 36
Number of TSG-panels 1
Number of distributor rows 0
Cover model Closed with prestamping

Downloads

Description

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 200 A, Rated current of the assembly of switchgear and controlgear InA 250 A, in RAL 7035, dimensions in mm (H x W x D): 1050 x 750 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars mm 5-pole, current transformer range CT mounting pad with CT rail 30 x 5 mm, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring Cu-Busbar 30 x 5 mm, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Busbar terminals should be ordered seperately, Grid unit 7 GU, Overall height 3, panel width 3, Space units 252, covers out of Plastic, Quick sealable connection, RAL 7035