Control unit 0-10 V REG-K/1-gang with manual mode, light grey
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
170,79 €
This price is valid until 31.12.25
Estimate delivery time at our warehouse (approx.):
By request
Technical Information
Item condition |
New |
Manufacture name |
Control unit 0-10 V REG-K/1-gang with manual mode, light grey |
Brand |
Schneider Electric
|
Categories |
Bus System Devices (KNX/Modbus)
|
Country of origin |
DE |
Mounting method |
DRA (DIN-rail adapter) |
Number of outputs |
1 |
Max. switching current (resistive load) |
16 A |
Bus system KNX |
Yes |
Max. switching power |
3600 W |
With bus connection |
Yes |
Width in number of modular spacings |
2.5 |
Other bus systems |
None |
Degree of protection (IP) |
IP20 |
Bus system KNX radio |
No |
Packing details
Packing level 1 |
3606485100043 |
Packing level 2 |
3606485100041 |
Other Technical data
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. control current |
100 mA |
Number of inputs for light sensor |
0 |
Bus system LON |
No |
Substation input |
No |
Local operation/hand operation |
Yes |
With LED indication |
No |
Interface 1-10 V |
Yes |
Radio frequent bidirectional |
No |
Min. depth of built-in installation box |
0 mm |
Downloads
Description
Control unit 0-10 V REG-K/1-gang with manual mode. For connecting devices with 0-10 V interface to KNX. With integrated bus coupler and screw terminals (230 V) or plug-in screw terminals (0-10 V). Each individual 230 V switch output can be operated manually with a manual switch. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. KNX software functions: Different dimming curves and dimming speeds, the same dimming time, memory function, ON/OFF delay, staircase time function with/without manual OFF function. Scenes (up to eight stored brightness values can be retrieved), central function, logic operation or priority control, blocking function, status feedback, behaviour on bus voltage recovery. Switch contact: for switching the electronic ballasts/transformers. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. Nominal current: 16 A, inductive load cos Phi 0.6. Nominal load: Incandescent lamps: AC 100 V, max. 1600 W. AC 230 V, max. 3600 W. AC 240 V, max. 3840 W. Halogen lamps: AC 100 V, max. 1086 W. AC 230 V, max. 2500 W. AC 240 V, max. 2608 W. Fluorescent lamps: AC 100 V, max. 1086 VA. AC 230 V, max. 2500 VA. AC 240 V, max. 2608 VA. parallel-compensated. Capacitive load: AC 100 V, max. 1600 W, 200 µF. AC 230 V, max. 3600 W, 200 µF. AC 240 V, max. 3840 W, 200 µF. 0-10 V interface: 0.12-100 mA. Voltage range: DC 0-10 V. Device width: 2.5 modules, approx. 45 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.