M22-K01 Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A
In stock: Yes
Vendor stock: No
Minimal order quantity: 20
Price (excl. VAT):
2,06 €
This price is valid until 31.12.25 or while stock lasts
Subtotal: 41,20 €
MOQ: 20
Estimate delivery time at our warehouse (approx.):
1-4 weeks
Technical Information
Item condition |
New |
Manufacture name |
M22-K01 Contact element, Screw terminals, Front fixing, 1 NC, 24 V 3 A, 220 V 230 V 240 V 6 A |
Brand |
EATON
|
Categories |
Signal & Control Modules
|
Country of origin |
DE |
Harmonized System Code |
8536 5080 00
|
Mounting method |
Front fastening |
Model |
Top mounting and integrable |
Rated operation current Ie at AC-15, 230 V |
6 A |
Type of electric connection |
Screw connection |
Number of contacts as normally closed contact |
1 |
Number of contacts as normally open contact |
0 |
Number of contacts as change-over contact |
0 |
Packing details
Packing level 1 |
4015082163785 |
Packing level 2 |
4015081846122 |
Other Technical data
Lamp holder |
None |
Number of fault-signal switches |
0 |
Description
Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Screw terminals, Fixing: Front fixing, Contacts N/C = Normally closed: 1 NC, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 15, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of HIA trip-indicating auxiliary contact: General trip indication '+', when tripped by shunt release, overload release , short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used , the NC contacts operates as a N/O contact and the N/O contact operates as an NC contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.