M22-CK20 Contact element, Cage Clamp, Front fixing, 2 N/O, 24 V 3 A, 220 V 230 V 240 V 4 A
In stock: No
Vendor stock: Yes
Minimal order quantity: 20
Price (excl. VAT):
7,72 €
This price is valid until 24.12.25
Subtotal: 154,40 €
MOQ: 20
Estimate delivery time at our warehouse (approx.):
4-6 weeks
Technical Information
Item condition |
New |
Manufacture name |
M22-CK20 Contact element, Cage Clamp, Front fixing, 2 N/O, 24 V 3 A, 220 V 230 V 240 V 4 A |
Brand |
EATON
|
Categories |
Signal & Control Modules
|
Country of origin |
DE |
Harmonized System Code |
8536 5080 00
|
Mounting method |
Front fastening |
Model |
Top mounting and integrable |
Rated operation current Ie at AC-15, 230 V |
6 A |
Type of electric connection |
Spring clamp connection |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
2 |
Number of contacts as change-over contact |
0 |
Packing details
Packing level 1 |
4015081075355 |
Packing level 2 |
4015081843343 |
Other Technical data
Lamp holder |
None |
Number of fault-signal switches |
0 |
Description
Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Cage Clamp, Fixing: Front fixing, Description: When using emergency switching off actuators M22-PV… max. 2 contact elements = 4 NC / N/O contacts, Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany, Contacts N/O = Normally open: 2 N/O, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Double contact, Description of HIA trip-indicating auxiliary contact: General trip indication '+', when tripped by shunt release, overload release , short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used , the NC contacts operates as a N/O contact and the N/O contact operates as an NC contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.