Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A image 1
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A image 2
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A image 3
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A image 4
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A thumbnail 1
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A thumbnail 2
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A thumbnail 3
Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A thumbnail 4

Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A

Order only
Price (excl. VAT):
96,37 €
This price is valid until 24.12.25
EAN: 4015081666751
MPN: 170166
Package: 1
Box: 13
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name Residual-current circuit breaker trip block for FAZ, 40A, 4pole, 100mA, type S/A
Brand EATON
Categories RCCB - (Residual Current Breakers)
Country of origin CZ
Harmonized System Code 8536 2010 00
Nominal current 40 A
Number of poles 4
Leakage current type A
Rated fault current 0.1 A
Nominal voltage 240-415 V
Degree of protection (IP) IP20
Ambient temperature during operating -25-40 °C

Packing details

Packing level 1 4015081666751
Packing level 2 9008790517099

Other Technical data

Rated insulation voltage Ui 440 V
Delay adjustable No
Max. delay time 40 ms
Surge current capacity 5 kA
Pollution degree 2
Frequency 50 Hz
Connectable conductor cross section solid-core 0.75-35 mm²
Connectable conductor cross section multi-wired 0.75-35 mm²
With interlocking device Yes
Rated fault current adjustable No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV

Description

Attachable residual current circuit-breaker unit FBSmV, 4 pole, Rated current In: 40 A, Rated short-circuit strength Icn:, Rated fault current IΔN: 0.1 A, Switchgear for industrial and advanced commercial applications

Similar items

Alternative EAN

Alternative EAN

Similar items
4015082860530 4015082901721 4015082901714 4015082847302 4015082482923 4015082482886
Alternative EAN
4015082860530 4015082901721 4015082901714 4015082847302 4015082482923
Alternative EAN
4015082901721 4015082901714 4015082482886 4015082482923 4015082847302