PFL7-16/1N/B/003-A RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A image 1

PFL7-16/1N/B/003-A RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A

In stock: Yes Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
46,33 €
This price is valid until 31.12.25 or while stock lasts
EAN: 4015082635350
MPN: 263535
Package: 1
Box: 60
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name PFL7-16/1N/B/003-A RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A
Brand EATON
Categories Earth Leakage Breakers (RCBO)
Harmonized System Code 8536 3030 00
Rated current 16 A
Rated voltage 230 V
Release characteristic B
Rated fault current 0.03 A
Leakage current type A
Degree of protection (IP) IP20
Number of protected poles 1
Ambient temperature during operating -25-40 °C
Number of poles (total) 2

Packing details

Packing level 1 4015082635350
Packing level 2 9007912271604

Other Technical data

Voltage type AC
Built-in depth 69.5 mm
Rated insulation voltage Ui 440 V
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 2
Frequency 50 Hz
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Connectable conductor cross section solid-core 1-25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Flush-mounted installation No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 10 kA

Description

This component integrates an RCBO (Residual Current Breaker with Overcurrent) providing protection against earth faults, overloads, and short circuits in electrical systems. It serves as a dual-function device for improved system safety and space efficiency in single-phase applications. ### Electrical Characteristics Rated current: 16 A. RCD sensitivity: 30 mA - protects against electrocution risks by disconnecting upon detecting leakage currents. MCB trip characteristic: B - designed for residential or light commercial settings; trips quickly at low overload levels like resistive loads. ### Mechanical Specifications Configuration: 1 pole + neutral - compact layout suitable for small enclosures requiring minimal wiring complexity. RCD trip type: A - responds to AC signals and pulsating DC leakage currents, common in most systems today. #### Technical Notes / Limitations - Not suitable for installations involving high inductive loads due to MCB Type B characteristics. - Requires correct orientation for installation (neutral on the designated side). - Operating range limited to single-phase systems only — not compatible with three-phase setups directly unless used selectively per phase/device load needs.