| Item condition | New |
| Manufacture name | Circuit breaker C60PV-DC 2-pole 25A 800VDC B-curve |
| Brand | Schneider Electric |
| Categories |
Circuit breakers 25A
|
| Country of origin* | CN |
| * The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager. | |
| Harmonized System Code | 8536 2010 00 |
| Rated current | 25 A |
| Rated voltage | 800 V |
| Release characteristic | B |
| Width in number of modular spacings | 4 |
| Number of poles (total) | 2 |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V | 0 kA |
| Packing level 1 | 3606480504112 |
| Packing level 2 | 3606480504116 |
| Packing level 3 | 3606480504112 |
| Voltage type | DC |
| Built-in depth | 44 mm |
| Frequency | 50 Hz |
| Rated insulation voltage Ui | 1000 V |
| Current limiting class | 0 |
| Over voltage category | 4 |
| Pollution degree | 2 |
| Explosion-proof | No |
| Degree of protection (IP) | IP20 |
| Number of protected poles | 2 |
| Concurrently switching neutral conductor | Yes |
| Connectable conductor cross section solid-core | 1-25 mm² |
| Connectable conductor cross section multi-wired | 1-16 mm² |
| Ambient temperature during operating | -25-70 °C |
| Flush-mounted installation | No |
| Additional equipment possible | Yes |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V | 0 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V | 0 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V | 0 kA |
| Rated impulse withstand voltage Uimp | 6 kV |
This Acti9 C60PV-DC product is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles and 25A In rated current and B tripping curve. The rated short circuit breaking capacity goes up to 3kA at 650VDC conforming to standard and at conforming to standard. This product complies with EN/IEC 60947-2 standard. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. It is designed to protect cables located between each string of photovoltaic modules. It will be installed in a string protection enclosure at the end of each string of photovoltaic modules combined with a switch. It is dedicated to multi string photovoltaic installations. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 1500 cycles. The Ue operational voltage is going from 800VDC. The Ui rated insulation voltage is 1000VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is . It can be mounted on DIN rail for modular installation. Its width is 8 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 72 mm x (H) 132.7 mm x (D) 77.4 mm. The weight is 0.545 kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.