AEG breakers and DIN modular devices represent the essential layer of circuit protection in industrial and commercial electrical systems. Designed for precision and endurance, AEG modular devices combine thermal-magnetic protection, compact DIN-rail format, and straightforward installation in distribution panels. Manufactured according to IEC 60898 and EN 60947 standards, they guarantee stability under continuous load, switching cycles, and short-circuit conditions.
These AEG electrical protection devices cover a wide current range — from 1 A to 125 A — with rated breaking capacities up to 10 kA. Engineers rely on them in automation boards, control panels, and energy distribution systems where space, reliability, and selectivity are key design parameters.
The AEG DIN modular breakers form the foundation of modular circuit protection. Compact and quick to install, they use standard 17.5 mm module widths and mount easily on 35 mm DIN rails. Available in single, double, triple, and four-pole configurations, they cover rated voltages up to 400 V AC and are compatible with both residential and industrial systems.
Each AEG miniature breaker features a bimetallic and magnetic trip mechanism for accurate overcurrent protection. The internal arc chambers and silver-graphite contacts extend service life and minimize heat buildup. For bulk purchasing, breakers are supplied in carton multiples, labeled with EAN and MPN codes for ERP integration and simplified BOM upload. Before large-scale installation, engineers typically verify tripping curves (B, C, or D) and terminal torque limits.
Beyond standard breakers, AEG modular devices include residual current circuit breakers (RCCBs), RCBOs, surge arresters, and control auxiliaries. These ensure combined overcurrent and residual current protection across various network topologies. The modular design allows fast expansion — each additional function simply clicks into place on the same DIN rail.
AEG overcurrent protection devices operate reliably from −25 °C to +55 °C and sustain up to 20,000 switching operations. Contact materials are silver-nickel alloy, with self-extinguishing thermoplastic housing rated to UL 94 V-0. Industrial buyers compare tripping sensitivity (30 mA, 100 mA, 300 mA), breaking capacity, and type of connection (pin or comb busbar). In wholesale supply, the consistent geometry of AEG din modules allows easy interchangeability with other European standards.
For control panels requiring compact protection, AEG miniature breakers deliver precision fault isolation within minimal space. Common in HVAC systems, lighting circuits, and industrial automation cabinets, they handle frequent switching and resist mechanical vibration. Their modular accessories — auxiliary contacts, shunt trips, signal relays — convert a standard MCB into a remote-controlled unit.
Advanced protection variants include combination RCBOs integrating both overcurrent and earth leakage detection in one housing. For higher selectivity, AEG also provides time-delayed and type-S models used in multi-level protection architectures. Procurement engineers value the consistent labeling, terminal identification, and modular compatibility that simplify stock management and maintenance.
AEG modular devices are compatible with standard 35 mm DIN-rail profiles and most enclosure systems used in European switchboards. Busbar spacing, interlocking mechanisms, and auxiliary contact slots are standardized. Integration with AEG surge protection and control accessories ensures cohesive system architecture.
The modular connection design supports both screw and quick-connect terminals, enabling hybrid installations. This flexibility allows OEMs to standardize panel layouts and simplify future upgrades or service replacements.
All AEG electrical protection devices comply with IEC 60898-1, EN 60947-2, and RoHS directives. Rated insulation voltage typically reaches 500 V, with impulse withstands up to 4 kV. Protection degree is IP20 when mounted, IP40 in enclosed boards. Terminals accept copper conductors up to 25 mm². Each production batch undergoes thermal, dielectric, and short-circuit testing, ensuring conformity for industrial and residential applications alike.
AEG modular circuit protection is installed across diverse segments — from manufacturing and renewable energy to infrastructure and building automation.
Procurement specialists usually assess rated current, pole configuration, tripping curve, and enclosure compatibility before placing bulk orders
Typical mistake — mixing tripping curves or incompatible terminal busbars. Always cross-verify part codes before bulk purchasing.
Bank of Lamps supplies the complete range of AEG breakers and DIN modular devices, AEG modular circuit protection, and AEG electrical protection devices for industrial and commercial applications.
We provide competitive B2B pricing, MOQ-based discounts, and fixed-term quotes for project orders. Our Latvia warehouse offers real-time stock visibility and partner access to AEG distribution hubs.
Quotes are processed within one hour; clients can order by EAN or MPN. We ship across the UK, Germany, Netherlands, France, Spain, Belgium, and the Baltics. For trusted customers — post-payment up to 30 days, consolidated deliveries, and full traceability documentation. Partner with Bank of Lamps for stable, repeatable supply of verified AEG DIN modular breakers and protection systems.