Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
Single-phase energy meter, without approval |
| Marca |
ELTAKO
|
| Categorías |
Contadores de energía
|
| País de origen* |
CN |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
9028 3011 00
|
| ETIM |
EC001506
|
| Tipo de fijación |
DRA (adaptador para carril DIN) |
| Ancho |
18 mm |
| Altura |
82 mm |
| Profundidad |
58 mm |
| Frecuencia |
50 Hz |
| Corriente máx. (Imax) |
32 A |
| Ancho en módulos |
1 |
| Grado de protección (IP) |
IP20 |
| Frecuencia de impulsos |
2000 Imp/kWh (kvarh) |
| Tipo de polos |
Monofásico |
| Tensión nominal (Un) N-L |
230 V |
| Corriente nominal (In) |
5 A |
Detalles del embalaje
| Nivel de embalaje 1 |
4010312501702, 4010312501702 |
| Nivel de embalaje 2 |
4010312501702 |
| Nivel de embalaje 3 |
4010312501702 |
Otros datos técnicos
| Modelo |
Medición directa |
| Apto para |
Consumo |
| Tipo de indicación |
Digital |
| Número total de dígitos (contador) |
7 |
| Tipo de contador |
Electrónico |
| Tipo de interfaz |
Otros |
| Tipo de energía |
Potencia activa |
| Tipo de tarifa |
Tarifa única |
| Mecanismo de disparo |
Sí |
| Calibrado |
No |
| Salida de impulsos |
Óptico |
| Tipo de impulso |
S0 |
| Clase de precisión |
B |
| Tipo de medición del perfil de carga |
No |
| Marcado EEC40 |
No |
| Con código de bloqueo |
No |
| Tensión nominal (Un) L-L |
230 V |
Descargas
Descripción
Maximum current 32A. Standby loss 0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.4 watt active power is neither metered nor indicated. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. Every 30 seconds, the display switches for 5 seconds from the accumulated active energy in kWh to the momentary consumption in watts. 1 phase conductor with a max. current up to 32A can be connected. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. If necessary, use spacer DS12. The inrush current is 20mA. The display can only be read when the power supply is on. However, the consumption is saved to a non-volatile memory and is displayed immediately after power restoration. Two N terminals for secure cross wiring of several counters. The digital display has 7 digits. Two decimal places are indicated up to 99999.99 kWh. Above 100000.0kWh there is only one decimal place. Power consumption is shown by a bar flashing at a rate of 1000 times per kWh. Error message: In the event of a connection error a LED in the display flashes.